COMSPHERE 392xPlus Modems

Table 5-3

(3 of 12)

392xPlus S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S41

Dial-Line Rate. Register determines the modem's data rate and modulation

Configure\Edit\

 

scheme for operation on dial lines.

Dial Line

 

Register has the following values:

 

 

1

= 14,400 (V.32bis)

 

 

2

= 12,000(V.32bis)

 

 

3

= 9600 (V.32bis)

 

 

4

= 7200 (V.32bis)

 

 

5

= 4800 (V.32bis)

 

 

6

= 2400 (V.22bis)

 

 

7

= 1200 (V.22)

 

 

8

= 1200 (212A)

 

 

10

= 0±300 (V.21)

 

 

11

= 0±300 (103J)

 

 

12

= 1200/75 (V.23)

 

 

13

= 75/1200 (V.23)

 

 

18

= 600/75 (V.23)

 

 

19

= 75/600 (V.23)

 

 

20

= 19,200 (V.32 terbo)

 

 

21

= 16,800 (V.32 terbo)

 

 

22

= 33,600

 

 

23

= 31,200

 

 

24

= 28,800 (V.34)

 

 

25

= 26,400 (V.34)

 

 

26

= 24,000 (V.34)

 

 

27

= 21,600 (V.34)

 

 

28

= 19,200 (V.34)

 

 

29

= 16,800 (V.34)

 

 

30

= 14,400 (V.34)

 

 

31

= 12,000 (V.34)

 

 

32

= 9600 (V.34)

 

 

33

= 7200 (V.34)

 

 

34

= 4800 (V.34)

 

 

35

= 2400 (V.34)

 

 

The factory setting is 28,800 (V.34).

 

 

 

 

S43

V.32bis Train. Register controls the modem's train time for V.32bis/V.32 mode.

Configure\Edit\

 

Register has the following values:

Dial Line

 

 

 

0

= Long

 

 

1

= Short

 

 

The factory setting is Long.

 

 

 

 

 

5-18

November 1996

3920-A2-GN31-30

Page 203
Image 203