DCP Operation

Pick Test

Port

>

Port1

 

Port2

F1

F2

F3

Select the appropriate port by pressing the corresponding F key. Press the key to scroll other ports into view.

The Pick Test Port screen does not appear in Singleport mode.

Test:P1:Pattern

Started

F1 F2 F3

The message Started appears on the LCD and the Test LED lights.

The port field (for example, P1 for Port 1) displays the port that is currently selected. You may see P1, P2, P3, or P4.

Test

P1:Pattern

>

BlksErrd=xxxxxxx

 

F1

F2

F3

BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. Select Clear to reset both block counters. In Singleport mode the message NoSync can appear as a value for BlksErrd while the modem's receiver is synchronizing. The message OvrFlw can appear as the value for BlksErrd if the counter overflows.

Press the

Press the

key to display BlksRcvd=xxxxxxx, number of blocks of data received.

key to display Clear. Select Clear to reset the block counters.

The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd continue counting.

If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.

To exit this function and remain in the Test branch, press the key. To exit and return to the

Top-Level menu, press the key.