Digital Bridging

Figure G-8 shows a sample for Digital Bridging.

Figure G-8. Sample Configuration Digital Bridge

3920Plus A Use TMp Control Template default configuration options with the following

 

exception:

 

 

MUX Mode

Set to DTE Bridge.

3920Plus

Use Sync Dial template default configuration options with the following

B, C

exceptions:

 

 

MUX Mode

Set to DTE Bridge.

 

NetworkPosition

Set to Control.

 

Diag Connection

Set to NMS(CC).

 

Tx Clock Source

Set to Port 1.

 

LSD Control

Set to Sim_Cntl_Car.

 

DTR Action

Set to Ignore.

3910Plus D Use Sync Dial template default configuration options with the following

exceptions:

 

NetworkPosition

Set to Control.

Diag Connection

Set to NMS(CC).

Tx Clock Source

Set to External.

LSD Control

Set to Sim_Cntl_Car.