COMSPHERE 392xPlus Modems

Table 3-8

(2 of 2)

Valid Ranges for VF Thresholds

VF Thresholds

Valid Ranges

Default Values

Far Echo

0±38 dBm

Above ±20 dBm

 

 

 

Frequency Offset

1 Hz to 15 Hz

Above 4 Hz

 

 

 

Phase Jitter

1 degree to 45 degrees

Above 9 degrees

 

 

 

Phase Hits

1 to 255 hits

20 hits per 15 minutes

 

 

 

Impulse Hits

1 to 255 hits

20 hits per 15 minutes

 

 

 

Gain Hits

1 to 255 hits

20 hits per 15 minutes

 

 

 

Drop Outs

1 to 255 dropouts

20 dropouts per 15 minutes

 

 

 

Test Branch

The Test branch of the Top-Level menu allows you to initiate various modem tests. Use these tests if you are having data communication problems, such as periodic character loss, random errors, or constant format errors. By the process of elimination, you can usually isolate the fault in your system.

There are six selections under Test: Abort, Self (Self-Test), Loc Analog Loop (Local Analog Loopback), Rem Digital Loop (Remote Digital Loopback), Loc Digital Loop (Local Digital Loopback), and Pattern. The only tests that can operate concurrently on a single modem are Pattern with a Local Analog Loopback and Pattern with a Remote Digital Loopback. If any test is operating, besides the two combinations just mentioned, it must be canceled before starting another test.

The Test branch only initiates and cancels tests. If parameters need to be set, refer to the Tests section in Chapter 4.

ªStatusº

Status

Configure

PList

Control

SubHS

Call_Setup

Tlk/Data

Security

Remote

Test

Abort

Self

Loc_Analog_Loop Rem_Digital_Loop

Loc_Digital_Loop

Pattern

 

 

 

 

 

 

 

 

 

 

Port

Port

Port

 

 

Select

Select

Select

3-54