COMSPHERE 392xPlus Modems

Table 5-3

(9 of 12)

392xPlus S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S74

Network Position Identification. Register identifies each modem as either a

Configure\Edit\

 

control or tributary modem.

Misc

 

Register has the following values:

 

 

0

= Tributary

 

 

1

= Control

 

 

The factory setting is Tributary.

 

 

 

 

S75

Network Management Address. Register determines the modem's network

Configure\Edit\

 

address. This address is used when accessing the modem from the 6700

Dial

 

Series NMS.

 

 

Enter a value from 0 (network address 001) to 255 (network address 256).

 

 

The factory setting is 0.

 

 

 

 

S76

V.32bis Autorate (Dial Line). Register determines if Autorating is used on dial

Configure\Edit\

 

lines when connected in V.32bis mode.

Dial Line

 

Register has the following values:

 

 

0

= Enable

 

 

1

= Disable

 

 

The factory setting is Enable.

 

 

 

 

S78

V.32bis Automode (Dial Line). Register allows the modem (when operating on

Configure\Edit\

 

dial lines) to automatically detect and connect to the remote modem's

Dial Line

 

modulation scheme.

 

 

Register has the following values:

 

 

0

= Enable

 

 

1

= Disable

 

 

The factory setting is Enable.

 

 

 

 

S82

V.32bis Autorate (Leased Line). Register determines if Autorating is used on

Configure\Edit\

 

leased lines when connected in V.32bis mode.

Leased Line

 

Register has the following values:

 

 

0

= Enable

 

 

1

= Disable

 

 

The factory setting is Enable.

 

 

 

 

S84

AT Command Mode. Register determines how the modem responds to valid

Configure\Edit\

 

and invalid AT commands.

DTE Dialer

 

Register has the following values:

 

 

0

= Normal

 

 

1

= No ERROR

 

 

2

= No Strap or ERROR

 

 

The factory setting is Normal.

 

 

 

 

 

5-24

November 1996

3920-A2-GN31-30

Page 209
Image 209
Paradyne 392xPLUS operation manual S74