COMSPHERE 392xPlus Modems
Table
(5 of 12)
392xPlus S-Registers
| Description | DCP LCD | |
| Command | ||
|
|
| Sequence |
|
|
| |
S46 | Auto Dial Backup. Register determines if the modem performs an automatic | Configure\Edit\ | |
| dial backup if the leased lines fail. | Leased Line | |
| Register has the following values: |
| |
| 0 | = Disable |
|
| 1 | = Enable |
|
| The factory setting is Disable. |
| |
|
|
| |
S47 | Auto Dial Standby. Register determines if the modem performs an automatic | Configure\Edit\ | |
| dial standby if in Dial Backup mode. | Leased Line | |
| Register has the following values: |
| |
| 0 | = Disable |
|
| 1 | = 15 minutes |
|
| 2 | = 1 hour |
|
| 3 | = 4 hours |
|
| 4 | = Test(2min) |
|
| 5 | = Adv 15min |
|
| 6 | = Adv 30min |
|
| 7 | = Adv 1 hr |
|
| 8 | = Adv2minTest |
|
| The factory setting is Disable. |
| |
|
|
| |
S48 | Configure\Edit\ | ||
| if the carrier signal on leased lines falls below ±26 dBm or ±43 dBm. | Leased Line | |
| Register has the following values: |
| |
| 0 | = ±43 dBm |
|
| 1 | = ±26 dBm |
|
| 2 | = ±33 dBm |
|
| The factory setting is country dependent (usually ±43 dBm). In France, the |
| |
| factory setting is ±26 dBm in |
| |
| operation. |
| |
|
|
| |
S49 | Buffer Disconnect Delay. Register determines how long the modem continues | Configure\Edit\ | |
| to transmit data stored in its buffers when the modem is commanded to | V42/MNP/Buffer | |
| disconnect by a locally attached DTE. |
| |
| Enter a value from 0±255 seconds. (A value of 0 disables this register.) The |
| |
| factory setting is 10 seconds. |
| |
|
|
| |
S51 | DTE RL (CT140). Register determines if the modem performs a remote digital | Configure\Edit\ | |
| loopback if it receives a CT140 signal from the DTE. | Tests | |
| Register has the following values: |
| |
| 0 | = Disable |
|
| 1 | = Enable |
|
| The factory setting is Disable. |
| |
|
|
|
|
November 1996 |