COMSPHERE 392xPlus Modems

Factory is a read-only (unchangeable) configuration area containing six sets of predefined configuration options labeled Sync Leased, Async Leased, TMp (Trellis Multipoint), Async Dial, Sync Dial, and UNIX Dial. If Sync Leased or Async Leased is selected, you must choose either Answer or Originate mode. If TMp is selected, you must choose either Control or Trib (Tributary) mode. These sets contain the most commonly used configurations options for modems installed into these hardware environments. These predefined configuration options are intended to give you a head start and only require a minimum of changes to the default settings. Factory default settings are listed in Appendix F.

Figure 4-1 graphically displays the interaction between the edit area and configuration areas as viewed from the perspective of the DCP.

CONTENTS OF Active (Saved) ARE AUTOMATICALLY COPIED

TO Active (Operating) WHEN A SAVE IS COMMANDED VIA THE

DCP, ON A RESET, OR ON POWER-UP.

Active (Operating)

Active (Saved)

Customer1

Customer2

Factory

S Sync Leased* (Answer/Originate)

S Async Leased* (Answer/Originate)

S TMp (Control/Trib)

S Async Dial

S Sync Dial*

S UNIX Dial

Load Edit

Area From

*Multiport mode

Save

To

EDIT AREA

ALLOWS YOU TO VIEW AND EDIT CONFIGURATION OPTIONS

ANY CHANGES MADE TO

CONFIGURATION OPTIONS

ARE SAVED TO Active (Saved),

Customer1, OR Customer2

Figure 4-1. DCP Configuration Process

4-2

November 1996

3920-A2-GN31-30

Page 119
Image 119
Paradyne 392xPLUS operation manual DCP Configuration Process