COMSPHERE 392xPlus Modems

The message Command Complete appears on the LCD to indicate that the tributary modem will be added to the control modem's poll list.

To exit this function and remain in the PList branch, press the key. To exit and return to the

Top-Level menu, press the key.

Acquire

The Acquire function does not appear in Remote mode.

Acquire allows you to acquire an active poll list consisting of all modems that are one tier downstream. A modem adds to its poll list all downstream modems that respond to a poll.

To access Acquire from the Plist branch, make the following selections:

Poll List:

 

<

Add

 

Acquire

F1

F2

F3

Press the

key until Acquire appears. Select Acquire.

NOTE

If an error message (OtherTestActive or Unable To Acquir) appears on the second line of the LCD, move up one level in the menu tree to clear the message and return to the PList Acquire branch. The OtherTestActive message indicates that a test is running which blocks the Acquire function. The Unable To Acquir message indicates that the diagnostic network is in a busy state.

Poll List:Acquir

Abort xxx yyy

F1 F2 F3

The address field (xxx) is incremented sequentially from 001 to 256 as polls are transmitted from the modem to the downstream modem(s). To be added to the modem's poll list, the device must respond to a poll after receiving its address. The Acquire function can be canceled by selecting Abort.

The number field (yyy) indicates the total number of devices that responded to the modem's polls thus far. These devices have been acquired for the poll list.

Select Abort or allow the function to complete.

3-34

November 1996

3920-A2-GN31-30

Page 71
Image 71