COMSPHERE 392xPlus Modems

Table 5-2

(9 of 9)

392xPlus AT Commands

AT

 

 

Description

DCP LCD

 

 

Command

Command

 

 

 

 

 

 

Sequence

 

 

 

 

 

 

 

 

 

 

\Nn

Error Control Mode.

 

 

Configure\Edit\

 

\N0

Buffer Mode.

 

V42/MNP/Buffer

 

 

 

 

\N1

Direct Mode.

 

 

 

\N2

MNP or Disconnect.

 

 

 

\N3

MNP or Buffer.

 

 

 

\N4

V.42/MNP or Disconnect.

 

 

 

\N5

V.42/MNP or Buffer.

 

 

 

\N6

LAPM or Disconnect.

 

 

 

\N7

LAPM or Buffer.

 

 

 

 

 

\Qn

Flow Control of DTE, Flow Control of Modem.

Configure\Edit\

 

 

 

Flow Control

Flow Control

V42/MNP/Buffer

 

 

 

 

 

 

 

of DTE:

of Modem:

 

 

 

\Q0

Disable

Disable

 

 

 

\Q1

XON/XOFF

XON/XOFF

 

 

 

\Q2

CTS to DTE

Disable

 

 

 

\Q3

CTS to DTE

RTS to Mdm

 

 

 

\Q4

XON/XOFF

Disable

 

 

 

\Q5

Disable

XON/XOFF

 

 

 

\Q6

Disable

RTS to Mdm

 

 

 

 

 

\Tn

No Data Disconnect Timer.

 

Configure\Edit\

 

\T0

Disable.

 

 

Line Dialer

 

 

 

 

 

\Tn

Where n is a value from 1 to 255 in 1-minute increments.

 

 

NOTE: The factory default value is country dependent.

 

 

 

 

 

 

 

\Xn

XON/XOFF Passthrough Flow Control.

 

Configure\Edit\

 

\X0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

\X1

Enable.

 

 

 

 

 

 

 

%An

Error Control Fallback Character.

 

Configure\Edit\

 

%An

Where n is an ASCII value from 0 to 127. Factory default is 013

V42/MNP/Buffer

 

 

 

 

ASCII.

 

 

 

 

 

 

 

%Cn

MNP5 Data Compression.

 

Configure\Edit\

 

%C0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

%C1

Enable.

 

 

 

 

 

 

 

 

IHn

V.42bis Compression.

 

 

Configure\Edit\

 

IH0

Disable.

 

 

V42/MNP/Buffer

 

 

 

 

 

IH1

Enable (Transmit (TX) only).

 

 

 

IH2

Enable (Receive (RX) only).

 

 

 

IH3

Enable (Transmit (TX) and Receive (RX)).

 

 

 

 

 

 

 

5-14

November 1996

3920-A2-GN31-30

Page 199
Image 199
Paradyne 392xPLUS operation manual N5, X0