Table 3-7 provides information about the Status Backup screens. The first column lists all possible configurations for the modem's currently active line. The second column lists all possible configurations for the modem's inactive lines. The third column provides information about the inactive line condition.

XXXX represents the condition code of the inactive line.

 

 

 

Table 3-7

 

 

Backup Status Screens

 

 

 

 

Active Line

Inactive Line

 

Possible Inactive/Backup Line Condition

1st Screen Display

2nd Screen Display

 

 

 

 

 

 

 

Line=Pri 4w APL

Bckup:2wAPL=XXXX

 

Good indicates that line continuity is detected.

or

or

 

 

Bad indicates that line continuity is not detected.

Line=Pri 2w APL

Bckup : Dial

=(blank)

 

 

???? indicates that the line condition is unknown (Backup

 

 

 

 

 

 

 

 

Facility Check is making its first determination of the line

 

 

 

 

conditions since the last retrain).

 

 

 

 

blank indicates that the BackupLineCheck configuration

 

 

 

 

option is disabled or not available. Refer to the BackupLine

 

 

 

 

Check configuration option in the Leased Line section of

 

 

 

 

Chapter 4.

 

 

 

 

 

Line=Bkup 2w APL

Pri 4w APL

=XXXX

 

Good indicates the line condition is good.

or

or

 

 

Bad indicates the line condition is bad.

Line = Dial Backup

Pri 2w APL =XXXX

 

 

???? indicates the line condition is unknown (Lease

 

 

 

 

 

 

 

 

Lookback has not had enough time to make an initial

 

 

 

 

appraisal of the line conditions since the last retrain).

 

 

 

 

blank indicates the Lease Lookback option is disabled.

 

 

 

 

Refer to the BackupLine Check configuration option in the

 

 

 

 

Leased Line section of Chapter 4.

 

 

 

 

Line=Dial Only

No second screen

 

NOTE: When the modem is configured for Dial Only, there

 

display.

 

 

is no backup.

 

 

 

 

NOTE: The leased-line interface is disabled when the

 

 

 

 

factory default options are loaded from the Async

 

 

 

 

Dial, Sync Dial, or UNIX Dial templates.

 

 

 

 

Line=No Sync

No second screen

 

NOTE: No Sync appears when the modem is not trained on

 

display.

 

 

either the primary or backup line facility.

 

 

 

 

 

To exit this function and remain in the Status branch, press the key. To exit and return to the

Top-Level menu, press the key.

3920-A2-GN31-30

November 1996

3-27

Page 64
Image 64