DCP Operation

VF Thresholds Update

The VF Thresholds Update function allows you to set the thresholds that determine the Health and Status alarm conditions for the VF parameters. Refer to Table 3-8 in this section for VF thresholds and their valid ranges and default values.

To access VF_Thresh_Update from the Control branch, make the following selections:

Control:<

VF_Thresh_Update

F1 F2 F3

Press the key until VF_Thresh_Update appears. Press any function key to select

VF_Thresh_Update.

VF Thresholds

Edit

Save

Reset

F1

F2

F3

Select Edit.

In the following example, the RSL High threshold is changed from 09 (±dBm) to 10. This example demonstrates VF threshold editing and saving. With the exception of Signal Quality, all VF thresholds may be modified in this manner. Signal Quality uses a menu selection with possible values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF threshold is similar to editing and saving a configuration option. (For another example of editing and saving, refer to the Editing and Saving a Configuration Option section in Chapter 4.)

RSL High (- dBm)

Nxt

￿ 09

F1 F2 F3

In the example shown above, 09 is the upper (High) RSL threshold (in ±dBm). To change the

09 to 10, make the following selections:

RSL High (- dBm)

Nxt

￿ 19

r

F1

F2

F3

Select the F2 ( ￿ ) key to increment the number above the cursor ( 0 ) to 1.

3920-A2-GN31-30

November 1996

3-51