AT Command Set and
Table
(4 of 12)
392xPlus S-Registers
| Description | DCP LCD | |
| Command | ||
|
|
| Sequence |
|
|
| |
S44 | Configure\Edit\ | ||
| scheme for operation on either | Leased Line | |
| or Originate mode. |
| |
| Register has the following values: |
| |
| 1 | = 14,400 (V.32bis) |
|
| 2 | = 12,000 (V.32bis) |
|
| 3 | = 9600 (V.32) |
|
| 4 | = 7200 (V.32bis) |
|
| 5 | = 4800(V.32) |
|
| 6 | = 2400 (V.22bis) |
|
| 11 | = 14,400 (V.33) |
|
| 12 | = 12,000 (V.33) |
|
| 13 | = 9600 (V.29) |
|
| 14 | = 7200 (V.29) |
|
| 15 | = 4800 (V.29) |
|
| 16 | = 4800 (V.27bis) |
|
| 17 | = 2400 (V.27bis) |
|
| 18 | = 19,200 (V.32 terbo) |
|
| 19 | = 16,800 (V.32 terbo) |
|
| 20 | = 19,200 (TMp) |
|
| 21 | = 14,400 (TMp) |
|
| 22 | = 9600 (TMp) |
|
| 23 | = 7200 (TMp) |
|
| 24 | = 4800 (TMp) |
|
| 25 | = 2400 (TMp) |
|
| 26 | = 33,600 |
|
| 27 | = 31,200 |
|
| 28 | = 28,800 (V.34) |
|
| 29 | = 26,400 (V.34) |
|
| 30 | = 24,000 (V.34) |
|
| 31 | = 21,600 (V.34) |
|
| 32 | = 19,200 (V.34) |
|
| 33 | = 16,800 (V.34) |
|
| 34 | = 14,400 (V.34) |
|
| 35 | = 12,000 (V.34) |
|
| 36 | = 9600 (V.34) |
|
| 37 | = 7200 (V.34) |
|
| 38 | = 4800 (V.34) |
|
| 39 | = 2400 (V.34) |
|
| The factory setting is 28,800 (V.34). |
| |
|
|
| |
S45 | Leased TX Level2. Register determines the modem's transmit power output | Configure\Edit\ | |
| level over leased lines. | Leased Line | |
| Enter a value from 0 to ±15 dBm. The factory setting is 0 dBm. |
| |
|
|
|
|
2The range of allowable values is 0 through 15 in North America, and 1 through 15 in other countries. The default is country dependent.