AT Command Set and S-Registers

Table 5-3

(4 of 12)

392xPlus S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S44

Leased-Line Rate. Register determines the modem's data rate and modulation

Configure\Edit\

 

scheme for operation on either 2-wire or 4-wire leased lines in either Answer

Leased Line

 

or Originate mode.

 

 

Register has the following values:

 

 

1

= 14,400 (V.32bis)

 

 

2

= 12,000 (V.32bis)

 

 

3

= 9600 (V.32)

 

 

4

= 7200 (V.32bis)

 

 

5

= 4800(V.32)

 

 

6

= 2400 (V.22bis)

 

 

11

= 14,400 (V.33)

 

 

12

= 12,000 (V.33)

 

 

13

= 9600 (V.29)

 

 

14

= 7200 (V.29)

 

 

15

= 4800 (V.29)

 

 

16

= 4800 (V.27bis)

 

 

17

= 2400 (V.27bis)

 

 

18

= 19,200 (V.32 terbo)

 

 

19

= 16,800 (V.32 terbo)

 

 

20

= 19,200 (TMp)

 

 

21

= 14,400 (TMp)

 

 

22

= 9600 (TMp)

 

 

23

= 7200 (TMp)

 

 

24

= 4800 (TMp)

 

 

25

= 2400 (TMp)

 

 

26

= 33,600

 

 

27

= 31,200

 

 

28

= 28,800 (V.34)

 

 

29

= 26,400 (V.34)

 

 

30

= 24,000 (V.34)

 

 

31

= 21,600 (V.34)

 

 

32

= 19,200 (V.34)

 

 

33

= 16,800 (V.34)

 

 

34

= 14,400 (V.34)

 

 

35

= 12,000 (V.34)

 

 

36

= 9600 (V.34)

 

 

37

= 7200 (V.34)

 

 

38

= 4800 (V.34)

 

 

39

= 2400 (V.34)

 

 

The factory setting is 28,800 (V.34).

 

 

 

 

S45

Leased TX Level2. Register determines the modem's transmit power output

Configure\Edit\

 

level over leased lines.

Leased Line

 

Enter a value from 0 to ±15 dBm. The factory setting is 0 dBm.

 

 

 

 

 

2The range of allowable values is 0 through 15 in North America, and 1 through 15 in other countries. The default is country dependent.