General format of command URL

Every configuration can be set through URL with the POST method, by the Administrator only.

<general format> URL[?[name=value][&name=value]……]

<method>

POST <authorized user> root

System configuration URL

URL: /setup/system.cgi

NAME

VALUE

DESCRIPTION

 

 

 

host

<text string shorter than 15 characters>

system name

 

 

 

ledoff

yes

turn off front LED

 

no

turn off front LED

method

keep

keep date and time unchanged

 

auto

use NTP server to synchronize

 

 

 

 

manu

directly adjust date and time

 

 

 

date

<yyyy/mm/dd>

year, month and date separated by slash

 

 

 

time

<hh:mm:ss>

hour, minute and second separated by colon

 

 

 

ntp

<domain name or IP address>

NTP server

 

 

 

zone

-12 ~ 12

time zone, 8 means GMT +8:00

 

 

 

updateInterval

one hour

Synchronize with NTP hourly

 

 

 

 

one day

Synchronize with NTP daily

 

 

 

 

one week

Synchronize with NTP weekly

 

 

 

 

One month

Synchronize with NTP monthly

 

 

 

49

Page 49
Image 49
Hawking Technology HNC720G manual General format of command URL, System configuration URL