The Network Camera provides a general I/O terminal block with one digital input and one relay switch for device control. Pin 1 and Pin 2 can be connected to an external sensor device and the state of voltage can be monitored from the initial state 'LOW'. The relay switches Pin 3 and Pin 4 can be used to turn on or off an external device.
Consult with the dealer of the peripheral devices for correct installation.
1 | DI+ | INPUT (Max. 50mA, 12VDC) |
2 | DI- | INPUT (Initial state of DI is Low) |
3 | SW_COMMON | OUTPUT (open from SW_OPEN at initial state) |
4 | SW_NOPEN | OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC) |