32.[RSI]

This command resets the card ID's in the system. After sending this command, each card ID in the system will match the slot number of the card. Use this command along with the SID commands that follow. The [RSI] command MUST be used prior to changing Card ID's once they have already been set.

Command Format: [RSI]

Example:

Send the command [RSI] to the system with Unit ID 0. The card in slot 1 will have ID 1, the card in slot 2 will have ID 2 and so on.

33.[SIDn]

This command sets all the cards installed in the MultiTasker system to the same Card ID. After sending this command, all cards will be addressed with the same ID. Use caution when sending this command to a system with multiple board types.

Command Format: [SIDn]

n= Card ID (n = # from 1 to 99) Example:

Send the command [SID1] to the system. All the cards in the system now have ID 1. Any commands that are sent to Card ID 1 will be received and executed by each card.

34.[SIDnCi]

This command sets the Card ID of a single card to a number from 1 to 99.

Command Format: [SIDnCi]

n = Card ID (n = # from 1 to 99)

Ci = Slot Number (i = # from 1 to max slots)

Example:

Send the command [SID50C10] to set the ID of the card in slot #10 to an ID of 50.

35.[SID+]

This command sets the ID of all the cards in a system to their slot number plus an offset value.

Command Format: [SID+n]

n = Offset amount (n = # from 0 to 99)

The maximum Card ID is 99, so subtract the highest slot number from 99 to find the maximum offset. For example, in an 8 slot enclosure, the maximum offset would be 91. The slot number, 8, plus the offset, 91, equals 99.

Example:

There are two, 20 slot enclosures to be connected together during normal operation. The first unit will use the Card ID defaults which are equal to their slot numbers. The second unit will have the same Unit ID, but will have the card ID's offset by 20.

Connect the computer to the second unit only. Send the command [SID+20] to set the ID of all cards in the enclosure to their slot number plus 20. Reconnect both units to the computer.

The cards in the first unit will be referenced as Card ID's 1-20 and the cards in the second unit will be referenced by Card ID's 21-40.

36.[RSN]

This command reads the slot number of the card with a specified ID number, and returns the value to the system to be displayed in the terminal window. If more than one card has the same ID, each slot number will be displayed.

Command Format: [RSNCi]

Ci = Card ID (i = # from 1 to 99)

Example:

The card in slot #4 takes up four slots in the enclosure. Its ID was set to 1 since it is the first card installed in the system, reading from left to right. Send the command [RSNC1] to find the slot number of this card. The system responds with the following feedback:

4

400-0209-002

17

Page 18
Image 18
Altinex MT113-101, MT113-100 manual Rsi, SIDnCi, Sid+, Rsn

MT113-100, MT113-101 specifications

The Altinex MT113-101 and MT113-100 are innovative devices designed to enhance presentation applications in educational and corporate environments. These units are part of Altinex’s commitment to providing high-quality AV solutions, focusing on usability, versatility, and advanced technology.

One of the standout features of the MT113 series is its flexible connectivity options. The MT113-101 and MT113-100 are equipped with a variety of input ports, accommodating different devices and enhancing user experience. The units include HDMI, VGA, and audio inputs, making it easy to connect laptops, desktops, projectors, and other presentation equipment. The ease of connectivity allows users to switch between multiple sources effortlessly, promoting a seamless presentation experience.

Another notable characteristic is the built-in scaling technology. This feature allows the MT113 devices to adjust the resolution of the incoming signal to match the output requirements of the display. This ensures that presentations are delivered with optimal clarity, regardless of the device being used. Consequently, users enjoy crisp visuals and accurate color reproduction, which is vital for effective communication.

The MT113 units also prioritize user-friendliness. Their intuitive design includes straightforward controls, allowing even those with limited technical know-how to operate the system efficiently. This focus on ease of use is essential in environments such as classrooms and conference rooms, where time is often of the essence.

Additionally, the MT113 series is designed with robust build quality in mind. The devices are constructed to withstand the rigors of daily use, making them ideal for high-traffic environments. Their reliability is paramount, especially in corporate settings where presentations can significantly impact outcomes.

Moreover, both models are compact and can be easily integrated into various setups, whether wall-mounted or placed on a tabletop. This flexibility allows organizations to adapt the equipment to their specific spatial and functional needs.

In conclusion, the Altinex MT113-101 and MT113-100 are sophisticated yet user-friendly solutions designed to elevate the presentation experience. With their versatile connectivity options, advanced scaling capabilities, and durable design, these devices are well-suited for a range of applications in educational and professional settings. Their combination of functionality and ease of use makes them a valuable addition to any AV setup.