Step 4: Wiring Information (continued)

C B OW2 W Y RH RC G A

Terminal Designation Reference Guide

Conventional Gas/Oil/Electric Heating and Cooling Systems (No Heat Pump):

C--Common (power or hot) wire from secondary side of heating system transformer. (Note: This wire is required for thermostat operation. If you do not have a “C” wire, please call customer support at 1-866-545-5765,e-mail at homesettings@wayne-dalton.com, or contact your HVAC professional to review possible solutions.)

W--Heat return or 1st stage relay (controls heating system) W2 --2nd Stage heat relay

Y -- 1st stage compressor contactor (controls air conditioning system)

RH --

Power for Heating system (Notes: 1. If there is just one power wire (R or RH) connect it to RH

 

with jumper 3 ON (most systems are like this.) 2. Never short RH terminal to C terminal as

 

severe damage to your HVAC system will occur.)

RC --

Power for Cooling system.

G --

Fan control relay

A--3rd wire for 3-wire zoned hot water heating systems

Heat Pump Systems:

C--Common (power or hot) wire from secondary side of heating system transformer. (Note: This wire is required for thermostat operation. If you do not have a “C” wire, please call customer support at 1-866-545-5765,e-mail at homesettings@wayne-dalton.com, or contact your HVAC professional to review possible solutions.)

B--Changeover valve control (Powered in HEAT) (Note: Never connect B and O terminals together as severe damage to your HVAC system will occur.)

O--Changeover valve control (Powered in COOL) (Note: Never connect B and O terminals together as severe damage to your HVAC system will occur.)

W2 --

Auxiliary heat/2nd Stage heat relay

Y --

1st stage compressor contactor (controls air conditioning system and 1st stage of heat pump)

RH --

Power for heat pump. (Notes: 1. If there is just one power wire (R or RH) connect it to RH

 

with jumper 3 ON (most systems are like this.) 2. Never short RH terminal to C terminal as

 

severe damage to your HVAC system will occur.)

G --

Fan control relay

 