Alto-Shaam 10.10ESG D An Ge R, Leak Te Stin G, Never U Se An Open Flame To Leak Test, Dan Ge R

Models: 6.10ESG 10.20ESG 10.10ESG

1 32
Download 32 pages 51.33 Kb
Page 21
Image 21
LEAK TE STIN G

®

COMBITHERM

G A S S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

LEAK TE STIN G

If a

pres sure l eak

tes t above 1/2 psi is to be

 

per for med on the

b uil ding sup ply gas p

iping, t he

shu t-off ga s va lve an d ove n i nlet gas supply

line

must be disconnecte

d f rom the buil

ding suppl y

piping be fore

cond uct ing t he p ressure

test. F ailu re

to do s o m ay res ult i n da mage to

the

man ual gas

valve, gas c ompon ents in the oven, or both.

 

If any gas leak te sts are to be c ondu cted at pressu res

equ al to or below

1/2 psi, t he manu al gas shut- off

valve

upstre am of

 

th e o ven mu st be

 

turned off

before cond ucting

the tests.

 

 

 

 

Leak t esting of th e intern al oven p iping sys tem w as

co nducte d be

fore

 

shi ppi ng th e

oven

from the

fac tor y. If ad

dit ional testing is nee

ded, it s

hould

onl y be cond ucted a t norma l g as supply pres

sure s.

If t he t est ing is perform ed u sing co mbu stible

gas in

the p ipi ng, the le ak checking should be d one wit h a soap solu tion (bub ble c hecking).

The use of an electr onic combustibl e gas leak detector

is

hel pful, how ev er, t his

type of d etect or

can

be

oversensiti ve. Electro nic

detectors may ind

icate

false leaks from other source s which would not b

e

detecte d when checking wi th a liquid solution

to

verify a no -hazard ga s co nnectio n.

 

 

When sta rti ng the oven after initial inst allatio n, the gas lines must b e f ree of a ir. I t may tak e up t o 30 minutes to eliminate all air from th e lines . If, aft er this ti me the re is no pilot, call for facto ry assist ance.

NEVER U SE AN OPENDAN GE R

NEVER U SE AN OPEN

FLAME TO LEAK TEST.

GAS EXHA UST

The ov en is no

t de signe d f or direct

 

co nnection to

 

a c hi mne y

vent s ys tem or

fo r d ire ct

conne ction

to a horizo

nta l e xh aust s yst em.

 

 

 

ven til at ion

Th e ove n mu st be

inst alled

 

unde r a

ho od listed

to AN

SI /UL 70

5 (lat

est ed it ion),

an d the in

 

stall at io n

mus t

be comp

 

leted in

 

 

ac corda nce w

ith t

he A

NS I/N FPA 96-19 87,

St and ard f

 

or V enti lat io n Control and Fir

 

e

Pro tection of Commercial C

 

oo king O

pera tions.

 

Ov en operato

 

rs s ho uld be

inst ruc ted wit h reg ard

to t he hazar ds of p lacing

an y mat eria l on top

of

the ov en tha t wou

ld o

bst ruc t t he

flo w of flue

 

 

 

 

 

pr odu ct s

 

ou t th e

open ing of

 

 

 

 

the f lue

divert

er.

 

Oper at ors

 

 

 

 

shoul d

 

al so

 

be in

 

st ruc te d

 

 

 

 

wit h re gar d to

th e h aza rd s of

 

 

 

 

ho t

flu e

gas es

 

an d t

ha t an

y

 

 

 

 

ma ter ial

or

ite ms p

la ced on

 

 

 

 

 

top

of ,

or

in

fr on t o f

th e flue

 

 

 

 

 

de fect or c ou ld b e damaged

or

 

 

 

 

cause a fir

e h azard.

 

 

 

 

D AN GE R

BEFORE STARTIN G THE APPLIANCE, MAKE CERTAIN YOU DO NOT DETE CT TH E ODOR O F GAS.

IF THE ODOR OF GAS IS DETECTED:

DO NOT attempt to light any appliance.

DO NOT touch any electrical switches.

Extinguish any open flame.

Use a telephone OUTSIDE THE PROPERTY & IMMEDIATELY contact your gas supplier.

If unable to contact your gas supplier, contact the fire department.

GAS C OMB ITH ERM INS TA LLA TI O N M AN UAL #MN-28676

PG. 19

Page 21
Image 21
Alto-Shaam 10.10ESG, 10.20ESG D An Ge R, Leak Te Stin G, Never U Se An Open Flame To Leak Test, Gas Exha Ust, Dan Ge R