1 cfm = 0.47189 l/s

21 l/s = 3.6 m3/hr

Sizing (Example) for maximum airflow normally required.

HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per hour. To calculate, simply take the square footage of the house (including basement) and multi- ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.

Example:

SQFT of House

1100

 

Basement

1100

 

Total SQFT

 

2200

 

Height of ceiling

 

 

x

8

 

Cubic volume

17600

 

 

/

60

 

Maximum airflow required (CFM)

 

 

293

 

 

x 0.35

 

 

 

 

103

* Always consult your local code for sizing requirements in your area.

Alternate Method

 

Room classification

Number of rooms

CFM (L/s)

 

CFM Required

 

 

 

 

 

 

 

Master bedroom

 

x 20 cfm (10 l/s)

=

 

 

 

 

 

 

Basement

yes or no

if yes add 20 cfm / 10 l/s

=

 

 

 

if no = 0

 

 

 

Bedrooms

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Living room

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Others

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Kitchen

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Bathroom

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Laundry room

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

Utility room

 

x 10 cfm

(5 l/s)

=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Ventilation Requirements (add last column )

=