TROUBLESHOOTING

Problem

Causes

Solutions

 

 

 

 

 

 

 

Air is too dry

 

Dehumidistat control is set too low

Increase the desired level of humidity. Change ventilation mode from

 

 

 

 

 

continuous mode to standby.

 

 

 

 

Balance HRV

 

 

HRV out of balance

 

 

 

 

 

Air is too humid

 

Dehumidistat control is set too high

Reduce the desired level of humidity. Combine this step with use of con-

 

 

 

 

 

tinuous exchange mode.

 

 

Sudden change in temperature

Wait until outside temperature stabilizes (winter). Heating will also

 

 

 

 

 

improve situation.

 

 

Storing too much wood for heating

Store a majority of your wood outside. Even dried, a cord of wood con-

 

 

 

 

 

tains more than 20 gallons of water.

 

 

Dryer vent exhaust is inside home

Arrange outside vent for dryer.

 

 

Poor air circulating near windows

Open curtains or blinds. Bay or bow windows may require mechanical

 

 

 

 

 

method.

 

 

HRV out of balance

Balance HRV

 

 

Well sealed basement door is closed

Open the door or install a grill on the door.

 

 

 

 

 

Persistent condensation

 

Improper adjustment of dehumidistat con-

Reduce the desired level of humidity. Combine this with the use of con-

on window

 

trol

tinuous exchange mode.

 

 

HRV out of balance

Balance HRV

 

 

 

 

 

Poor Air Flows

 

-1/4” (6mm) mesh on the outside hoods

-Clean exterior hoods or vents

 

 

is plugged

-Remove and clean filter

 

 

-Remove and clean core

 

 

-Filters plugged

 

 

-Check and open grilles

 

 

-Core obstructed

 

 

-Have electrician check supply voltage at house

 

 

-House grilles closed or blocked

 

 

-Check duct installation

 

 

-Dampers are closed if installed

 

 

-Increase the speed of the HRV/ERV

 

 

-Poor power supply at site

 

 

-Have contractor balance HRV/ERV

 

 

-Ductwork is restricting HRV/ERV

 

 

 

 

 

 

-Improper speed control setting

 

 

 

 

-HRV/ERV airflow improperly balanced

 

 

 

 

 

 

 

 

Supply air feels cold

 

-Poor location of supply grilles, the airflow

-Locate the grilles high on the walls or under the baseboards, install

 

ceiling mounted diffuser or grilles so as not to directly spill the supply

 

 

may irritate the occupant

 

 

air on the occupant (eg. Over a sofa)

 

 

-Outdoor temperature extremely cold

 

 

-Turn down the HRV/ERV supply speed. A small duct heater (1kw)

 

 

 

 

 

could be used to temper the supply air

 

 

 

 

 

-Placement of furniture or closed doors is restricting the movement of

 

 

 

 

 

air in the home

 

 

 

 

 

-If supply air is ducted into furnace return, the furnace fan may need to

 

 

 

 

 

run continuously to distribute ventilation air comfortably

 

 

 

 

 

HRV and / or Ducts

 

-HRV air flows are improperly

-Note: minimal frost build-up is expected on cores before unit initiates

Frosting up

 

balanced

defrost cycle functions

 

-Have HVAC contractor balance the HRV

 

 

-Malfunction of the HRV defrost

 

 

 

 

 

 

system

 

 

 

 

 

 

 

Condensation or Ice

 

-Incomplete vapor barrier around

-Tape and seal all joints

Build Up in Insulated

 

insulated duct

-Tape any holes or tears made in the outer duct covering

Duct to the Outside

 

-A hole or tear in outer duct covering

-Ensure that the vapor barrier is completely sealed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 