Introducing the NEW Heat Recovery Ventilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core. The HRV then distributes the preheated fresh filtered air throughout the home by direct ductwork installed specifically for the HRV or through the ductwork of a forced-air system.

FEATURES:

Compact Design

Electrostatic Filters (washable)

Balancing Dampers Included In Installation Kit

(not factory installed)

External Screw Type Dry Contacts For Push Button Timers, Dehumidistats, Crank Timer & Digital Control.

Easy Core Guide Channels For Removing Core

Better Packaging For More Protection In Shipping

OPTIONAL CONTROLS

• DMFC

– Digital Multi-Function Control

MD-4W – Mechanical Low Voltage Dehumidistat with On/Off Switch

MD-2W – Mechanical Low Voltage Dehumidistat

RT-15M – 15 Minute Push Button Timer

CT-30M – 30 Minute Crank Timer

• AQS

– Air Quality Sensor

External screw type dry contacts (provided)

HRV Series

HRV 150 & HRV 200

SPECIFICATIONS

CASE 22 gauge galvanized steel on the HRV-200 & 24 gauge galvanized steel on the HRV-150. Baked powder coated paint. Insulated with 1" (25 mm) high density polystyrene foam to prevent condensation and meet the requirements of the Underwriters Laboratories 94HF.

MOTORS Two (2) German-manufactured, factory-balanced ebm™ motors with backward curved blades. Motors come with permanently lubricated sealed bearings guarantee long life and maintenance-free operation. Seven (7) year limited limited warranty.*

CORE Aluminum heat recovery core configured for an efficient cross-flow ventilation. Core is 9" x 9" (229 x 229

mm)with a 15" (380 mm) depth HRV-150 or 12" x 12"

(305 x 305 mm) with a 15" (380 mm) depth HRV-200. Cores are manufactured to withstand extreme temperature variations.

FILTERS Two (2) Washable Electrostatic Panel Type Air Filters, HRV-150 is 8.5" (216mm) x 15" (380mm) x 0.125" (3mm), HRV-200 is 11.75" (298mm) x 15" (380mm) x 0.125" (3mm).

CONTROLS External three (3) position (Low/Stand By/Medium) rocker switch that will offer continuous ventilation. We offer a variety of external controls. (see optional controls)

DEFROST A preset 5 minute defrost sequence is activated at an outdoor air temperature of 23˚F (-5˚C) and lower.

During the defrost sequence, the supply blower shuts down

&the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy.

The unit then returns to normal operation for 25 minutes, and continues cycle.

SERVICEABILITY Core, filters, motors and drain pan can be easily serviced through latched access door. Core conveniently slides out with ease on an improved railing system. Electrical box, placed on the outside of the unit, can also be easily accessed.

* For details concerning warranties, please visit your local dealer.

The product is manufactured by Fantech, Inc. Fantech reserves the right to modify, at any time and without notice, any or all of this product's features, designs, components and specifications.