INTERNAL UNIT
To reduce the risk of leakage the internal unit must be hung absolutely level. The water catcher in the internal unit with the condensation water drainage connected to it must be clean and free from any obstruction, so that the condensation water can drain off unhindered (otherwise risk of leakage).
Once the place for the internal unit has been determined, you can start fixing the internal unit. Note that fixing it is your own responsibility.
A. Attachment plate
Mount the attachment plate level on a firm base, measure well and draw holes for the screws.
TIP. Fix the plate not too firmly with a screw, put the plate in horizontal position with the help of a spirit level, and then mark the holes for the other screws. Take the screw out again, drill all holes, put plugs in and screw the plate tight.
Drill the 8 holes 6.4 mm (2.5”) wide and 30 mm deep. Use the additionally supplied plugs.
Fix the attachment plate firmly with the additionally supplied screws.
B. Hole through the wall for the duct
The hole with a diameter of 65 mm and slanting a bit towards the outside in a downward direction
Area for the hole.