IMPORTANT

Auto restart

The air conditioner will automatic restart when electricity is restored after a power cut. If in doubt, check the settings.

Range of internal thermostat

The internal thermostat can be set at a desired temperature between 18 and 30 °C. Note that whether the desired value is achieved depends on conditions in the room.

Range of heat pump function

The heat function can be used when the external temperature is approximately 10 °C or higher.

Note that it may not operate properly at lower external temperatures.

Capacity

The required cooling or heating capacity depends greatly on the location and/or use of the room where the air conditioner is installed. Strong sunlight and the presence of people, lights or equipment create an additional heat load.

Normal living spaces require about 100 W per square metre of floor surface. In strong sunlight or if other sources of heat are present, this may be as much as 350 W/m2.

For your air conditioner’s specifications, see pages 58/59.

Tip: on warm days, let the air conditioner cool the room as much as possible during the night. Cold walls and furniture will help to keep the room pleasant during use. Avoid strong sunlight.

Emergency start

In the event of a problem, the air conditioner can be operated using the emergency button under the panel in the interior unit. Open the front panel and press the button.

The air conditioner will:

-heat if the room temperature is 20 °C or less

-cool if the room temperature is 25 °C or more

and for values in between: dehumidify in a model without a heat pump and in a model with a heat pump in fan mode.