EXTERNAL UNIT

GB

EXTERNAL UNIT

Drainage pipe

Fix the drainage pipe to the base plate. If necessary a drainage hose (not included) leading to a drain can be attached to this.

On the ground or on the roof the condensation water can usually drain off freely.

Check that this does not cause nuisance to anyone and that it can cause no damage.

Fixing the external unit

Place the rubber footrests and screw the unit thoroughly on a strong base.

Keep 50 cm of free space around the unit

The external unit can be fitted on special base plates or on a wall support.Consult your installer

A

 

B

 

C

 

D

Connecting the electricity

Unscrew the protective cover [A] [B].

The electricity for the external unit comes from the internal unit through the cable with a special little pin contact which clicks into the contact socket [C].

Check that this connection is properly fixed [D].