51
Switch #8 -When the computer is being programmed in the automatic mode, a dryness level of 1 through 9
must be selected. In some cases, a dryness level of more than 9 is required. If this switch is
opened, the computer will triple the dryness level selected (for a maximum level of 27).
The dip switches have been factory set for the customer’s requirements. These switches should only be
changed if the dryer’s operational requirements change.
Operating Instructions - Non-Coin Computer Dryer
The door must be closed for ALL data entries. During data entry, pressing “Clear/Stop” once will clear the
present entry. Pressing it twice in succession resets the computer to its initial position. If the door is opened
during a cycle, both basket (tumbler) and heat will stop. The cycle will continue only after the door is closed and
“Enter/Start” is pressed. However, the computer will continue to count the time while the door is open.
A. COMPUTER DISPLAY CODES
FILL Empty Dryer Prior to Data Entry (Auto/Manual Mode)
Fd Display Prior to Data Entry When Auto Cycle is Selected,
or Indicates Empty Dryer for Auto Only Dryer
Ld Load Drying Time (Manual Mode)
LC Load Cooling Time (Manual Mode)
FFabric Selection (Manual Mode)
Sr Select Reversing (Reversing Dryers with Reverse/Non-Reverse Selectability)
Dr Dryer is Operating in Drying Mode
CL Dryer is Operating in Cool Down Mode
CC Cycle Complete, Dryer has Finished a Complete Cycle and Shut Off
dSFL Dryer Sensor Circuit Failure
door Door Switch Failure, or Attempted Start has been made with Door Open
The non-coin computer dryer is available in an automatic only mode, or an automatic/manual selectable mode. It
can also have the reversing basket (tumbler) option.