PL09 - Left Coin Slot Denomination (LCdE)
In the case of a single coin acceptor, this program setting is determined by the value of the coin acceptor (i.e.,
25¢).
When a dual coin acceptor is used, this program setting is determined by the left coin slot acceptor value (lower
coin value). Program settings are from a minimum of 1 to a maximum of 9999.
PL10 - Right Coin Slot Denomination (rCdE)
This program needs only to be set when a dual coin acceptor is used. The program setting is determined by the
value of the right coin acceptor slot (higher value). Program settings are from a minimum of 1 to a maximum of
9999. When used in conjunction with the Left Coin Slot Denomination program, the Phase 3 microprocessor
controller (computer) automatically calculates the ratios necessary for coin insertion time values.
PL11 - Time Per Left Coin (tPLC)
This program sets a specific value in time for each coin inserted. In the case of a dual coin acceptor, the Time
Per Right Coin is automatically calculated by the left and right coin slot denomination ration.
PL12 - Amount To Start (AtSt)
This program sets the “Amount To Start” the dryer and can be programmed from a minimum of 1 to a maximum
of 9999.
PL13 - Minimum Amount For Additional Time (AFAt)
This program needs only be set when the Phase 3 microprocessor controller (computer) is set in the “Accumulative
Coin” (“ACOn”) mode (PL01). The value set for this program is what will have to be inserted for more time
after the “Amount To Start” (“AtSt”) has been inserted.
Example No. 1:“Amount To Start” (“AtSt”) is 50¢ for 30 minutes and an additional 50¢ is required for more
time. In this example, PL13 should be set for 50¢.
PL14 - Maximum Automatic Dryness Time (Adrt)
This program is used only when the Phase 3 microprocessor controller (computer) is set in the automatic mode
or free dry mode. This program controls the maximum time the dryer will run even if the Dryness Level
program (PL02) has not been reached.