4
SECTION I

INTRODUCTION

The Phase 3 computerized system is a fully programmable, highly sophisticated dryer control system. ADC has
designed the Phase 3 to be the most versatile and reliable coin-op control system available.
To eliminate as many moving parts as possible, ALL Phase 3 programming is done through the membrane
switch on the front of the control panel. The switch (PS) that puts the computer into the program mode is a
single, sealed, military specification toggle switch. This toggle switch (PS) eliminates the possibility of switch
failure due to an accumulation of lint or moisture.

PHASE 3 FEATURES

Programmable
Changes in programs are made at the temperature selection keyboard (touch pad), and actual programs are
displayed for verification.
Adjustable Time
Programmable from a minimum of 1 minute to a maximum of 99 minutes in 1 minute increments.
Coin Acceptor Denominations
Values of the coin acceptors are programmable from a minimum of 1 to a maximum value of 9999 for any U.S.
or foreign coin denomination.
Amount To Start
Programmable from a minimum value of 1 to a maximum value of 9999 in increments of one (1).
Accumulative Time
This program yields a specific value of time for any coin entry made after the “Amount To Start” has been
inserted.
Accumulative Coin
This program selection requires that a specific value of coin(s) be inserted for additional time, programmable for
any minimum amount.
Coin Count
The number of coins inserted, including a separate display program for optional dual coin acceptors, can be
viewed through the Phase 3 computer’s light emitting diode (L.E.D.) display.