19
Accumulative Coin (ACOn)When this program mode (“ACOn”) is selected, additional time can only be achieved when the “Amount For
Additional Time” (“AFAt”) (PL13) has been inserted.
Single Coin AcceptorExample No. 1:Using a 25¢ coin acceptor with the desired “Amount To Start” (“AtSt”) being 50¢ for 24
minutes, the Phase 3 microprocessor controller (computer) would yield more time (24 minutes)
only when an additional 50¢ is inserted. For this application, the “Time Per Left Coin” (“tPLC”)
program (PL11) is determined as follows:
Formula: (Total Vend Time/AtSt)(LCdE) = tPLC
(24/50)(25) = 12 minutes (tPLC)
Settings: PL09 (LCdE)............ 25
PL10 (rCdE) .............12
PL11 (tPLC) .............50
PL12 (AtSt)............... 50
Dual Coin AcceptorWith dual coin acceptor the “Time Per Left Coin” (“tPLC”) is determined as follows:
Formula: (Total Vend Time/AtSt)(LCdE) = tPLC
Example No. 1:Using a 10¢/25¢ dual coin acceptor and the desired “Amount To Start” (“AtSt”) is 50¢ for 20
minutes and the “Amount For Additional Time” (“AFAt”) is set for 20¢, each additional 20¢
would yield 8 minutes.
Formula: (20/50)(10) = 4 minutes (tPLC)
Settings: PL09 (LCdE)............ 10
PL10 (rCdE) .............25
PL11 (tPLC) ...............4
PL12 (AtSt)............... 50
PL13 (AFAt)............. 20
Example No. 2:If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the “Amount To Start” (“AtSt”)
is 35¢ for 14 minutes and the “Amount For Additional Time” (“AFAt”) is set for 25¢, each
additional 25¢ inserted would yield 10 minutes.
Formula: (14/35)(10) = 4 minutes (tPLC)
Settings: PL09 (LCdE)............ 10
PL10 (rCdE) .............25
PL11 (tPLC) ...............4
PL12 (AtSt)............... 35
PL13 (AFAt)............. 25