American Power Conversion AP9615 Troubleshooting continued, Troubleshooting suggestions continued

Models: AP9615

1 22
Download 22 pages 59.16 Kb
Page 17
Image 17
Troubleshooting continued

Troubleshooting continued

Troubleshooting

suggestions,

continued

LED

Action

Cause

Solution

 

 

 

 

 

 

 

Check that the correct

 

 

 

cable is in use and

 

 

 

verify that the

 

 

32 consecutive

connected equipment

 

 

is set to operate at 10

 

 

collisions have

Partition

On

Mbit and half-duplex

caused the port

mode.

 

 

 

 

to partition.

 

 

As collisions reduce,

 

 

 

 

 

 

the port reconnects

 

 

 

and the Partition

 

 

 

LED turns off.

 

 

 

 

Table 2: Suggestions for Troubleshooting, continued