Alarm Item
Controls and Indicators
Connecting the Cables
Warranty
LVD Reset
RJ45 Ethernet Connector
Battery Management
How to
Page 7
Image 7
Figure
2.1-2
MX28B-400
+24 Vdc System Wiring Diagram with Battery LVD
MX28B400 +24 VDC User’s Manual
Page 3
Page 6
Page 8
Page 7
Image 7
Page 6
Page 8
Contents
Page
Table of Contents
Remote Monitoring
Revision Date Description
Revision History
General Precautions
Safety First
General Information
Introduction
2 MX28B-400 +24 Vdc System Wiring Diagram with Battery LVD
How to Use This Manual
Room / Location
Installation
Mechanical Installation
Unpacking Equipment
Ventilation
AC Power Connections
Planning the Battery installation
Battery Connections
Connecting the Cables
2 Battery Temperature Probe Installation
Battery Temperature Probe Installation
DC System Grounding
DC Circuit Breakers
DC Power Output Over-Current Protection
Breaker Part Number Adaptor Size Rating
Load Cable Size Considerations
Plug-in Circuit Breaker Installation
Circuit Breaker Connections 60-100 Amps
Circuit Breaker Connections 1 to 50 Amps
Smart Cable DB9 Connection
Monitoring and Relay Output Connections
GMT Fuse Option
Front Panel DB9 Connection
Relay Output Connections
RJ45 Ethernet Connector
NO-NC-C
External Alarm Input Connections
Initial Power-Up and Checkout
Rectifier Module Installation
Battery Maximum Recharge Rate default = 12A
System Parameters Verification/Adjustment
Full System Power Up
Technical Description
Operation
Rectifier Management
System Voltage Control
System Status and Alarm Reporting
System Management
System Output Capacity
DC Distribution
Battery Management
Battery Charging and Protection
Battery Temperature Compensation
Battery/Load Low Voltage Disconnect
Controls and Indicators
Front Panel User Interface
Parameter Locations, Descriptions, and Default Values
Status Alarms System Modules Batt PIN OEM
Switzer Av
Alarm Item
No Alarms
Address
50 a
Minor
22.00
Batt Max Rechm+
00mV
Comp Lknee
Comp Method m+
Comp TC
Hw LVD Alm
Fuse 1 Alm
Hw Batt C Almm+
Hw Batt T Almm+
LVD Option
Disable
LVD Reset
Lamp Test
Sec
Out-Rly
Relay
Out-Rly 1 Dly m+
24.9
Rect CL Alm
Rect 1 CL
Rect 1 Curr
Sys Current
Rect Stdby Almm+
Rect 1 Stdby
Store Cfg
Test Maj Rly
Sys Temp
26.7
Sys Voltage
Control Unit Menu Structure
Status Alarms
V e l C o n d L e v e l I r d L e v e l U r t h L e v e l
Sysout AP Alias
MOD Modrec EM Modules Batt Rect Conv CIR SET-ALM Param
MOD Modcir
MOD Modlvd MT LVD SET-ALM Param
Front Panel LED Indicators
External Alarm Inputs Input Relays
Alarm Outputs Output Relays
Physical Connections
Command and Monitoring Protocol
Remote Monitoring
Description
1MRF28H27BV50 Rectifiers
Specifications
AC Input
1MRF28H27BV Rectifiers
Rectifiers
DC Output with either Rectifier
Pscu
Power Shelf Control Unit
Environmental
Mechanical
Compliance