American Standard 2580 installation instructions Water Supply Connections

Models: 2580

1 8
Download 8 pages 44.73 Kb
Page 7
Image 7
Manual background

7 WATER SUPPLY CONNECTIONS

NOTE: FLEXIBLE SUPPLIES ARE NOT INCLUDED AND HAVE TO BE

PURCHASED SEPARATELY.

Connect water supplies to FAUCET (1) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use adjustable wrench to tighten connections.

Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

1

2

COUPLING NUT

8 FINISH DRAIN INSTALLATION

Position BIDET fixture and secure to floor.

Insert lift rod into lift rod guide.

Position EXTENSION ROD (1) onto POP-UP ROD (2) and tighten THUMBSCREW (3).

Remove one end of CLIP (4) from PIVOT ROD (7) by squeezing ends together while sliding.

Insert PIVOT ROD (7) into second or third hole in EXTENSION ROD (1) and reassemble CLIP (4). (EXTENSION ROD (1) may need to be bent.)

Adjust STOPPER height by repositioning EXTENSION ROD (1) and tightening THUMBSCREW (3).

Using metal TAILPIECE (5), make connection to the TRAP (6).

2

1

3

HotCold

Manual backgroundManual background FERRULE

3

1

5

6

7

4

9 TEST INSTALLED FITTING

1

With HANDLES (1) in OFF

 

position, turn on WATER SUPPLIES (2) and check all connections for leaks.

Operate both handles to flush water lines thoroughly. Turn diverter to rim wash and bidet spray.

Operate Lift Rod (3) and fill Bidet with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Bidet. Adjust stopper height by repositioning Lift Rod (3) and tightening Thumbscrew (5).

Release DRAIN STOPPER (4) and check all drain connections for leaks. Tighten if necessary.

25

3

10 SERVICE

To change direction of handle

rotation, proceed

 

as follows:

2

 

Turn valve to OFF position.

 

 

 

 

 

Remove HANDLE and

 

 

 

 

 

 

ADAPTER if present.

 

 

Remove SPRING CLIP (1).

 

 

 

 

 

 

Lift STOP WASHER (2),

 

 

 

 

 

 

turn 90° and replace.

 

 

Replace SPRING CLIP (1).

 

 

 

 

 

 

Replace HANDLE ASSEMBLY.

 

 

SPRAY (3) may accumulate dirt causing distorted and reduced water flow. Unscrew and remove SPRAY (3) and rinse clean.

Replace SPRAY (3) and operate handles several times from OFF to ON position. Do not force, handles turn only 90˚.

90°

1

Manual backgroundManual background 3

4

11 CARE INSTRUCTIONS:

2

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE

M968293