American Water Heater AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250 Venting Installation

Models: AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250 Commercial Gas Water Heaters

1 80
Download 80 pages 24.27 Kb
Page 22
Image 22

VENTING INSTALLATION

Breathing Hazard - Carbon Monoxide Gas

,Install vent system in accordance with codes.

,Do not operate water heater if flood damaged.

,Special consideration must be taken with installations above 10,000 feet (3,048 m) refer to high altitude

section of this manual.

, Do not operate if soot buildup.

, Do not obstruct water heater air intake with insulating jacket or blanket.

, Do not place chemical vapor emitting products near water heater.

, Gas and carbon monoxide detectors are available.

,Never operate the heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, fire, explosion or asphyxiation.

,Analyze the entire vent system to make sure that condensate will not become trapped in a section of vent pipe and therefore reduce the open cross sectional area of the vent.

Breathing carbon monoxide can cause brain damage or death.

Always read and understand the instruction manual.

1HYHURSHUDWHWKHZDWHUKHDWHUXQOHVVLWLVYHQWHGWRWKHRXWGRRUV

7KHLQVWUXFWLRQVLQWKLVVHFWLRQRIWKHPDQXDOPXVWEHIROORZHG

WRDYRLGFKRNHGFRPEXVWLRQRUUHFLUFXODWLRQRIÀXHJDVHV6XFK

FRQGLWLRQV FDXVH VRRWLQJ RI WKH FRPEXVWLRQ FKDPEHU EXUQHUV DQGÀXHWXEHVDQGFUHDWHVDULVNRIDVSK\[LDWLRQ

GENERAL VENTING INFORMATION

7KH ZDWHU KHDWHUV FRYHUHG LQ WKLV PDQXDO DUH RSHUDWLRQDOO\ HTXLYDOHQW WR &DWHJRU\ ,9 DSSOLDQFHV DQG PD\ EH LQVWDOOHG LQ HLWKHUD3RZHU9HQWRU'LUHFW9HQWFRQ¿JXUDWLRQ

CATEGORY IV APPLIANCE

&DWHJRU\ ,9 DSSOLDQFHV RSHUDWH ZLWK D SRVLWLYH YHQW H[KDXVW 

VWDWLF SUHVVXUH DQG ZLWK YHQW JDV WHPSHUDWXUHV ORZ HQRXJK WR SURGXFHFRQGHQVDWHLQWKHYHQWSLSLQJ

POWER VENT CONFIGURATION

3RZHU 9HQW FRQ¿JXUDWLRQV GHULYH DOO FRPEXVWLRQ DLU IURP WKH URRP ZKHUH WKH\ DUH LQVWDOOHG DQG GLVFKDUJH DOO ÀXH JDVHV WR WKH RXWGRRU DWPRVSKHUH WKURXJK D VHDOHG YHQW H[KDXVW  SLSH 3RZHUYHQWFRQ¿JXUDWLRQVKDYHRQHYHQWSLSHFRQQHFWHGWRWKH

ZDWHUKHDWHUZKLFKFDQEHWHUPLQDWHGLQDYHUWLFDORUKRUL]RQWDO

DUUDQJHPHQW6HH)LJXUHDQG)LJXUHRQSDJH

DIRECT VENT CONFIGURATION 'LUHFW9HQWFRQ¿JXUDWLRQVGHULYHDOOFRPEXVWLRQDLUGLUHFWO\IURP

WKH RXWGRRU DWPRVSKHUH WKURXJK D VHDOHG LQWDNH DLU SLSH DQG GLVFKDUJH DOO ÀXH JDVHV WR WKH RXWGRRU DWPRVSKHUH WKURXJK D VHDOHGYHQW H[KDXVW SLSH'LUHFW9HQWFRQ¿JXUDWLRQVKDYHWZR SLSHV FRQQHFWHG WR WKH ZDWHU KHDWHU RQH YHQW SLSH DQG RQH LQWDNHDLUSLSH'LUHFW9HQWFRQ¿JXUDWLRQVFDQEHWHUPLQDWHGLQ RQH RI VL[ GLIIHUHQW DUUDQJHPHQWV 6HH )LJXUH  RQ SDJH  WKURXJK)LJXUHRQSDJH

GENERAL VENTING INSTRUCTIONS

7KHVHLQVWUXFWLRQVPXVWEHIROORZHGRQDOOLQVWDOODWLRQV

 DO NOTLQVWDOOWKHZDWHUKHDWHULQD3RZHU9HQWFRQ¿JXUDWLRQ XQOHVV WKHUH LV DGHTXDWH VXSSO\ RI IUHVK DLU VHH $LU 5HTXLUHPHQWV RQ SDJH  ,I WKH LQVWDOODWLRQ VSDFH GRHV QRWSURYLGHDQDGHTXDWHVXSSO\RIIUHVKDLUWKHZDWHUKHDWHU PXVWEHLQVWDOOHGLQD'LUHFW9HQWFRQ¿JXUDWLRQ

 ,I WKH ZDWHU KHDWHU LV WR EH LQVWDOOHG LQ D EHDXW\ VKRS EDUEHU VKRS FOHDQLQJ HVWDEOLVKPHQW D ODXQGU\ ZLWK GU\

FOHDQLQJHTXLSPHQWRUDQ\VSDFHZLWKFRQWDPLQDWHGDLULWLV LPSHUDWLYH WKDW WKH ZDWHU KHDWHU V  EH LQVWDOOHG LQ D 'LUHFW 9HQW FRQ¿JXUDWLRQ VR WKDW DOO DLU IRU FRPEXVWLRQ LV GHULYHG IURPWKHRXWGRRUDWPRVSKHUH

 7KHYHQWDQGLQWDNHDLUSLSLQJPXVWWHUPLQDWHRXWGRRUV

 7KHPLQLPXPFOHDUDQFHIURPFRPEXVWLEOHPDWHULDOVIRUWKH YHQW H[KDXVW DQGLQWDNHDLUSLSLQJVKDOOEHLQFKHV9HQW

SLSLQJSDVVLQJWKURXJKDFRPEXVWLEOHZDOORUFHLOLQJPXVWEH

DFRQWLQXRXVUXQ QRMRLQWV 

 7KHZDWHUKHDWHUPXVWEHSURWHFWHGIURPIUHH]LQJGRZQGUDIWV GXULQJVKXWGRZQSHULRGV

 7KHYHQW H[KDXVW SLSHPXVWQRWEHFRPELQHGRUFRQQHFWHG WRDQ\RWKHUDSSOLDQFH¶VYHQWV\VWHPRUFKLPQH\

 7KH LQWDNH DLU SLSH PXVW QRW EH FRPELQHG RU FRQQHFWHG WR DQ\RWKHUDSSOLDQFH¶VLQWDNHDLUSLSLQJ

 /RFDWHWKHZDWHUKHDWHUZKHUHWKHYHQW H[KDXVW DQGLQWDNH

DLUSLSLQJZLOOUHPDLQZLWKLQWKHPD[LPXPHTXLYDOHQWOHQJWKV

DOORZHG6HH9HQWLQJ5HTXLUHPHQWVRQSDJH

 'RQRWLQVWDOOWKHYHQWRULQWDNHDLUSLSLQJLQDPDQQHUWKDWZLOO DOORZZDWHUWREHWUDSSHGLQWKHSLSLQJ

9HQWSLSHVPXVWEHSLWFKHGDPLQLPXPRIDLQFKSHUIRRW

EDFNWRWKHZDWHUKHDWHU WRDOORZGUDLQDJHRIFRQGHQVDWH 

'RQRWDQFKRUWKHYHQWRULQWDNHDLUSLSHGLUHFWO\WRIUDPHG

ZDOOVÀRRUVRUFHLOLQJVXQOHVVUXEEHULVRODWLRQSLSHKDQJHUV

DUHXVHGWRSUHYHQWYLEUDWLRQQRLVHIURPEHLQJWUDQVPLWWHG

8VHRQO\DSSURYHGYHQWLQWDNHDLUSLSHVL]HVDQGPDWHULDOV

6HH9HQWLQJ5HTXLUHPHQWVRQSDJH

8VH RQO\ IDFWRU\ VXSSOLHG YHQW DQG LQWDNH DLU RU FRQFHQWULF WHUPLQDWLRQV6HHWKH9HQWLQJ5HTXLUHPHQWVRQSDJH

'R QRW ORFDWH WKH YHQW H[KDXVW  RU LQWDNH DLU WHUPLQDWLRQV ZKHUH WKH\ ZRXOG EH REMHFWLRQDEOH GXH WR QRLVH DW WKH WHUPLQDWLRQ V 7KLVLQFOXGHVORFDWLRQVFORVHWRRUDFURVVIURP

ZLQGRZVDQGGRRUV

'LUHFWYHQWLQJLQWRGHDGDLUVSDFHVVXFKDVDOOH\VDWULXPV

DQG LQVLGH FRUQHUV FDQ FDXVH UHFLUFXODWLRQ RI ÀXH JDVHV 5HFLUFXODWLRQ RI ÀXH JDVHV ZLOO FDXVH VRRWLQJ SUHPDWXUH IDLOXUH RI WKH KHDW H[FKDQJHU DQG LFLQJ RI WKH FRPEXVWLRQ DLU LQWDNH GXULQJ VHYHUH FROG ZHDWKHU 7R SUHYHQW WKH

UHFLUFXODWLRQ RI ÀXH JDVHV PDLQWDLQ DV PXFK GLVWDQFH DV SRVVLEOHEHWZHHQWKHLQWDNHDLUDQGYHQWWHUPLQDWLRQV

'RQRWORFDWHWKHYHQWWHUPLQDWLRQRYHUDSXEOLFDUHDZKHUH

FRQGHQVDWHRUYDSRUFDQFDXVHDQXLVDQFHRULFHKD]DUG

(QVXUHWKHVFUHHQVLQWKHIDFWRU\VXSSOLHGWHUPLQDWLRQVDUH

VHFXUHO\LQVWDOOHGWRSUHYHQWEORFNDJHLQWKHYHQWV\VWHP

6WUHVVOHYHOVLQSLSH¿WWLQJVFDQEHVLJQL¿FDQWO\LQFUHDVHGE\ LPSURSHU LQVWDOODWLRQ ,I ULJLG SLSH FODPSV DUH XVHG WR KROG WKHSLSHLQSODFHRULIWKHSLSHFDQQRWPRYHIUHHO\WKURXJKD ZDOOSHQHWUDWLRQWKHSLSHPD\EHVWUHVVHGRUKLJKWKHUPDO VWUHVVHVPD\EHIRUPHGZKHQWKHSLSHKHDWVXSDQGH[SDQGV ,QVWDOODFFRUGLQJO\WRPLQLPL]HVXFKVWUHVVHV

(QVXUHWKHLQWDNHDLUFRQQHFWLRQ7HH¿WWLQJLVRULHQWHGSURSHUO\ RQ$+&*PRGHOVVHHSDJHIRULQVWUXFWLRQV

&DUHIXOO\UHDGWKH9HQWLQJ5HTXLUHPHQWVRQSDJHDQGWKHQ

SURFHHGWRWKH9HQWLQJ,QVWDOODWLRQ6HTXHQFHRQSDJH

22

Page 22
Image 22
American Water Heater AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250 Venting Installation, General Venting Information