7KHUHLVDULVNLQXVLQJIXHOEXUQLQJDSSOLDQFHVVXFKDVJDVZDWHU

KHDWHUVLQURRPVJDUDJHVRURWKHUDUHDVZKHUHJDVROLQHRWKHU

ÀDPPDEOH OLTXLGV RU HQJLQH GULYHQ HTXLSPHQW RU YHKLFOHV DUH VWRUHGRSHUDWHGRUUHSDLUHG)ODPPDEOHYDSRUVDUHKHDY\DQG WUDYHODORQJWKHÀRRUDQGPD\EHLJQLWHGE\WKHZDWHUKHDWHU¶V LJQLWHURU0DLQ%XUQHUÀDPHVFDXVLQJ¿UHRUH[SORVLRQ

)ODPPDEOHLWHPVSUHVVXUL]HGFRQWDLQHUVRUDQ\RWKHUSRWHQWLDO ¿UHKD]DUGRXVDUWLFOHVPXVWQHYHUEHSODFHGRQRUDGMDFHQWWR

WKHZDWHUKHDWHU

CLEARANCE TO COMBUSTIBLE MATERIALS

7KH ZDWHU KHDWHUV FRYHUHG LQ WKLV PDQXDO DUH DSSURYHG IRU LQVWDOODWLRQRQFRPEXVWLEOHÀRRULQJ7KHFOHDUDQFHWRFRPEXVWLEOH DQG QRQ FRPEXVWLEOH FRQVWUXFWLRQ PDWHULDOV LV  LQFKHV RQ WKH EDFNDQGVLGHVRIWKHZDWHUKHDWHU7KHVHZDWHUKHDWHUVDUHDOVR

DSSURYHGIRULQVWDOODWLRQLQDQDOFRYH

NOTE:$GHTXDWHFOHDUDQFHIRUVHUYLFLQJVKRXOGEHPDLQWDLQHG

RQDOOLQVWDOODWLRQV6HH6HUYLFH&OHDUDQFHEHORZ

ALCOVE

CLEARANCES TO COMBUSTIBLE

 

AND NON COMBUSTIBLE

 

CONSTRUCTION MATERIALS

TOP COVER

 

 

0

 

0

WATER

0

HEATER

 

FRONT

 

 

FRONT

FRONT VIEW

TOP VIEW

 

Figure 7

SERVICE CLEARANCE

$VHUYLFHFOHDUDQFHRILQFKHV FP VKRXOGEHPDLQWDLQHG IURP VHUYLFHDEOH SDUWV VXFK DV WKH 7 3 YDOYH FRQWURO V\VWHP FRPSRQHQWVJDVYDOYHFOHDQRXWRSHQLQJGUDLQYDOYHWKHYHQW FRQQHFWLRQ H[KDXVWHOERZ DQGWKHFRQGHQVDWHGUDLQ/HDYHDV

PXFK URRP DV SRVVLEOH DERYH WKH ZDWHU KHDWHU DQG QHDU WKH H[KDXVWHOERZIRUWKLVUHDVRQ6HH)LJXUHRQSDJH

INTAKE AIR AND VENT PIPE CLEARANCES

7KHPLQLPXPFOHDUDQFHIURPFRPEXVWLEOHPDWHULDOVIRUWKHYHQW

H[KDXVW DQGLQWDNHDLUSLSLQJVKDOOEHLQFKHV9HQWRULQWDNH

DLUSLSLQJSDVVLQJWKURXJKDFRPEXVWLEOHZDOORUFHLOLQJPXVWEH

DFRQWLQXRXVUXQ QRMRLQWV 

EXTENDED VENT TERMINATIONS

7KHZDWHUKHDWHUVFRYHUHGE\WKLVPDQXDOFDQEHLQVWDOOHGXVLQJ

LQFKSLSHIRUWKHLQWDNHDLUDQGRUYHQWSLSLQJXSWRDPD[LPXP

RIHTXLYDOHQWIHHW P 7KHLQWDNHDLUDQGRUYHQWSLSLQJ

FDQEHH[WHQGHGXSWRHTXLYDOHQWIHHW P E\LQVWDOOLQJ

LQFKSLSH6HHWKH9HQWLQJ5HTXLUHPHQWVRQSDJH

7KH ZDWHU KHDWHU VKLSV IURP WKH IDFWRU\ ZLWK WZR    LQFK WHUPLQDWLRQV WKDW DUH ƒ 39& HOERZV ZLWK D GHEULV VFUHHQ LQVWDOOHG:KHQLQFKLQWDNHDLURUYHQWSLSHLVLQVWDOOHGIDFWRU\ VXSSOLHGLQFKWHUPLQDWLRQVPXVWEHXVHG

&RQWDFW\RXUORFDOGLVWULEXWRURUFDOOWKHSDUWVGHSDUWPHQWSKRQH

QXPEHUOLVWHGRQWKHEDFNFRYHURIWKLVPDQXDOWRRUGHULQFK

WHUPLQDWLRQ V 

OPTIONAL CONCENTRIC TERMINATIONS

7KHZDWHUKHDWHUVFRYHUHGLQWKLVPDQXDOFDQEHLQVWDOOHGLQD

'LUHFW9HQWFRQ¿JXUDWLRQXVLQJDQRSWLRQDOFRQFHQWULFWHUPLQDWLRQ

6HH&RQFHQWULF7HUPLQDWLRQ,QVWDOODWLRQRQSDJH

HARD WATER

:KHUH KDUG ZDWHU FRQGLWLRQV H[LVW ZDWHU VRIWHQLQJ RU WKH WKUHVKROG W\SH RI ZDWHU WUHDWPHQW LV UHFRPPHQGHG 7KLV ZLOO

SURWHFW WKH GLVKZDVKHUV FRIIHH XUQV ZDWHU KHDWHUV ZDWHU SLSLQJ DQG RWKHU HTXLSPHQW 6HH 0DLQWHQDQFH RQ SDJH  IRU

VHGLPHQWDQGOLPHVFDOHUHPRYDOSURFHGXUHV

CIRCULATION PUMPS

$FLUFXODWLQJSXPSLVXVHGZKHQDV\VWHPUHTXLUHVDFLUFXODWLQJ ORRSRUWKHUHLVDVWRUDJHWDQNXVHGLQFRQMXQFWLRQZLWKWKHZDWHU KHDWHU 6HH WKH :DWHU 3LSLQJ 'LDJUDPV EHJLQQLQJ RQ SDJH 

IRULQVWDOODWLRQORFDWLRQRIFLUFXODWLQJSXPSV

6HH &LUFXODWLRQ 3XPS :LULQJ 'LDJUDPV RQ SDJH  IRU

HOHFWULFDO KRRNXS LQIRUPDWLRQ ,QVWDOO LQ DFFRUGDQFH ZLWK WKH FXUUHQWHGLWLRQRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$RUWKH &DQDGLDQ(OHFWULFDO&RGH&6$&

$OOEURQ]H FLUFXODWLQJ SXPSV DUH UHFRPPHQGHG IRU XVH ZLWK FRPPHUFLDOZDWHUKHDWHUV

6RPHFLUFXODWLQJSXPSVDUHPDQXIDFWXUHGZLWKVHDOHGEHDULQJV DQG GR QRW UHTXLUH IXUWKHU OXEULFDWLRQ 6RPH FLUFXODWLQJ SXPSV PXVW EH SHULRGLFDOO\ RLOHG 5HIHU WR WKH SXPS PDQXIDFWXUHU¶V LQVWUXFWLRQVIRUOXEULFDWLRQUHTXLUHPHQWV

INSULATION BLANKETS

Breathing Hazard - Carbon Monoxide Gas

Do not obstruct water heater air intake with insulating blanket.

Gas and carbon monoxide detectors are available.

Install water heater in accordance with the instruction manual.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

,QVXODWLRQEODQNHWVDUHDYDLODEOHWRWKHJHQHUDOSXEOLFIRUH[WHUQDO XVH RQ JDV ZDWHU KHDWHUV EXW DUH QRW QHFHVVDU\ ZLWK WKHVH SURGXFWV7KHSXUSRVHRIDQLQVXODWLRQEODQNHWLVWRUHGXFHWKH VWDQGE\ KHDW ORVV HQFRXQWHUHG ZLWK VWRUDJH WDQN KHDWHUV 7KH ZDWHUKHDWHUVFRYHUHGE\WKLVPDQXDOPHHWRUH[FHHGWKH(QHUJ\ 3ROLF\$FWVWDQGDUGVZLWKUHVSHFWWRLQVXODWLRQDQGVWDQGE\KHDW ORVVUHTXLUHPHQWVPDNLQJDQLQVXODWLRQEODQNHWXQQHFHVVDU\

6KRXOG \RX FKRRVH WR DSSO\ DQ LQVXODWLRQ EODQNHW WR WKLV KHDWHU \RX VKRXOG IROORZ WKHVH LQVWUXFWLRQV 6HH WKH )HDWXUHV

DQG &RPSRQHQWV VHFWLRQ RI WKLV PDQXDO IRU LGHQWL¿FDWLRQ RI FRPSRQHQWVPHQWLRQHGEHORZ)DLOXUHWRIROORZWKHVHLQVWUXFWLRQV FDQUHVWULFWWKHDLUÀRZUHTXLUHGIRUSURSHUFRPEXVWLRQSRWHQWLDOO\ UHVXOWLQJLQ¿UHDVSK\[LDWLRQVHULRXVSHUVRQDOLQMXU\RUGHDWK

‡ DO NOTDSSO\LQVXODWLRQWRWKHWRSRIWKHZDWHUKHDWHUDVWKLV

ZLOOLQWHUIHUHZLWKVDIHRSHUDWLRQRIWKHEORZHUDVVHPEO\

‡ DO NOTFRYHUWKHFRQWUROV\VWHP/&'RQWRSRIWKHZDWHUKHDWHU ‡ DO NOTFRYHUWKH7HPSHUDWXUH3UHVVXUH5HOLHI9DOYH

‡ DO NOTFRYHUWKHLQVWUXFWLRQPDQXDO.HHSLWRQWKHVLGHRIWKH

ZDWHUKHDWHURUQHDUE\IRUIXWXUHUHIHUHQFH

‡ DO REWDLQ QHZ ZDUQLQJ DQG LQVWUXFWLRQ ODEHOV IURP WKH

PDQXIDFWXUHU IRU SODFHPHQW RQ WKH EODQNHW GLUHFWO\ RYHU WKH H[LVWLQJODEHOV

‡ DO LQVSHFW WKH LQVXODWLRQ EODQNHW IUHTXHQWO\ WR PDNH FHUWDLQ LW

GRHVQRWVDJWKHUHE\REVWUXFWLQJFRPEXVWLRQDLUÀRZ

13

Page 13
Image 13
American Water Heater Commercial Gas Water Heaters Extended Vent Terminations, Optional Concentric Terminations

AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250, Commercial Gas Water Heaters specifications

American Water Heater's Commercial Gas Water Heaters, particularly the AHCG/HCG3 60T 120 and AHCG3/HCG3 100T 250 models, stand out in the market for their impressive performance and reliable efficiency. Designed to meet the demanding needs of commercial applications, these gas water heaters provide an optimal solution for businesses requiring consistent hot water supply.

One of the main features of the AHCG/HCG3 series is its exceptional heat capacity. The models are engineered to deliver high recovery rates, ensuring that adequate hot water is available even during peak demand periods. The AHCG/HCG3 60T 120 can yield a robust output, ideal for smaller to medium-sized facilities, while the AHCG3/HCG3 100T 250 is designed for larger operations that require enhanced capacity.

These water heaters incorporate innovative technologies to maximize efficiency. The use of a high-efficiency burner system significantly reduces gas consumption, earning these models an Energy Factor rating that complies with modern energy standards. Additionally, the inclusion of a direct vent design allows for safe and efficient exhaust management, further promoting the energy-saving capabilities of these units.

The design of these commercial water heaters prioritizes durability and longevity. Constructed with heavy-duty components, including a corrosion-resistant water tank, these models are built to last, reducing the need for frequent replacements and maintenance. They also feature an advanced control system that monitors and adjusts the operation for optimal performance, enhancing user experience while decreasing operational costs.

Another notable characteristic of the AHCG/HCG3 series is their flexibility in installation. Both the 60T 120 and the 100T 250 models offer various venting options, which means they can easily fit into the existing infrastructure of many commercial facilities. This versatility facilitates a seamless integration process, saving time and resources during installation.

With a commitment to providing effective hot water solutions, American Water Heater continues to innovate, making the AHCG/HCG3 series a valuable addition to any commercial establishment. From restaurants to laundromats and beyond, these gas water heaters deliver reliable performance, ensuring that businesses can operate smoothly and efficiently.