WATER LINE CONNECTIONS

 

T&P VALVE DISCHARGE PIPE

7KHZDWHUSLSLQJLQVWDOODWLRQPXVWFRQIRUPWRWKHVHLQVWUXFWLRQV DQG WR DOO ORFDO DQG QDWLRQDO FRGH DXWKRULW\ KDYLQJ MXULVGLFWLRQ *RRGSUDFWLFHUHTXLUHVWKDWDOOKHDY\SLSLQJEHVXSSRUWHG

5HDG DQG REVHUYH DOO UHTXLUHPHQWV LQ WKH IROORZLQJ VHFWLRQV EHIRUHLQVWDOODWLRQRIWKHZDWHUSLSLQJEHJLQV

 0L[LQJ9DOYHVRQSDJH

 'LVKZDVKLQJ0DFKLQHVRQSDJH

 7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHRQSDJH

 &ORVHG6\VWHPVDQG7KHUPDO([SDQVLRQRQSDJH

 )RU PXOWLSOH ZDWHU KHDWHU LQVWDOODWLRQV VHH :DWHU 3LSLQJ 'LDJUDPVEHJLQQLQJRQSDJH

WATER PIPING DIAGRAMS

7KLVPDQXDOSURYLGHVGHWDLOHGZDWHUSLSLQJGLDJUDPVIRUW\SLFDO

PHWKRGVRIDSSOLFDWLRQIRUWKHZDWHUKHDWHUVVHH:DWHU3LSLQJ

'LDJUDPVEHJLQQLQJ

7KHZDWHUKHDWHUPD\EHLQVWDOOHGE\LWVHOIRUZLWKDVHSDUDWH VWRUDJH WDQN :KHQ XVHG ZLWK D VHSDUDWH VWRUDJH WDQN WKH FLUFXODWLRQ PD\ EH HLWKHU E\ JUDYLW\ RU E\ PHDQV RI FLUFXODWLQJ SXPS:KHQDFLUFXODWLQJSXPSLVXVHGLWLVLPSRUWDQWWRQRWH WKDWWKHÀRZUDWHVKRXOGEHVORZVRWKDWWKHUHZLOOEHDPLQLPXP

RIWXUEXOHQFHLQVLGHWKHZDWHUKHDWHUVWRUDJHWDQN

$GMXVW ÀRZ E\ WKURWWOLQJ D IXOO SRUW EDOO YDOYH LQVWDOOHG LQ WKH FLUFXODWLQJOLQHRQWKHRXWOHWVLGHRIWKHSXPS1HYHUWKURWWOHÀRZ RQWKHVXFWLRQVLGHRIDSXPS6HHWKH:DWHU3LSLQJ'LDJUDPV EHJLQQLQJRQSDJH

NOTE:,QDGGLWLRQWRWKHIDFWRU\LQVWDOOHG7HPSHUDWXUH3UHVVXUH 5HOLHI 9DOYH 7 3 YDOYH  RQ WKH ZDWHU KHDWHU HDFK UHPRWH VWRUDJHWDQNWKDWPD\EHLQVWDOOHGDQGSLSHGWRDZDWHUKHDWLQJ DSSOLDQFH PXVW DOVR KDYH LWV RZQ SURSHUO\ VL]HG UDWHG DQG DSSURYHG7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHLQVWDOOHG

&DOO WKH WROO IUHH WHFKQLFDO VXSSRUW SKRQH QXPEHU OLVWHG RQ WKH EDFNFRYHURIWKLVPDQXDOIRUIXUWKHUDVVLVWDQFHLQVL]LQJD7 3

YDOYHIRUUHPRWHVWRUDJHWDQNV

THERMOMETERS (NOT SUPPLIED)

7KHUPRPHWHUV DUH LQVWDOOHG LQ WKH ZDWHU SLSLQJ V\VWHP DV D

PHDQV RI GHWHFWLQJ WKH WHPSHUDWXUH RI WKH KRW ZDWHU VXSSO\ DW FULWLFDO SRLQWV LQ WKH V\VWHP )LHOG VXSSOLHG WKHUPRPHWHUV VKRXOGEHREWDLQHGDQGLQVWDOOHG6HH:DWHU3LSLQJ'LDJUDPV RQSDJH

WATER (POTABLE) HEATING AND SPACE HEATING

 $OOZDWHUSLSLQJFRPSRQHQWVFRQQHFWHGWRWKHZDWHUKHDWHU WKDWDUHIRUVSDFHKHDWLQJDSSOLFDWLRQVVKDOOEHVXLWDEOHIRU XVHZLWKSRWDEOHZDWHU

 7R[LF FKHPLFDOV VXFK DV WKRVH XVHG IRU ERLOHU WUHDWPHQW PXVW1(9(5EHLQWURGXFHGLQWRWKLVV\VWHP

 7KH ZDWHU KHDWHUV FRYHUHG LQ WKLV PDQXDO PD\ QHYHU EH FRQQHFWHG WR DQ\ H[LVWLQJ KHDWLQJ V\VWHP RU FRPSRQHQW V 

SUHYLRXVO\XVHGZLWKQRQSRWDEOHZDWHUKHDWLQJDSSOLDQFH

 :KHQ WKH V\VWHP UHTXLUHV ZDWHU IRU VSDFH KHDWLQJ WKDW H[FHHGVDIHWHPSHUDWXUHVDWGRPHVWLFZDWHU¿[WXUHVDPL[LQJ YDOYHPXVWEHLQVWDOOHGVHH0L[LQJ9DOYHVRQSDJH

 7KHVH ZDWHU KHDWHUV FDQQRW EH XVHG LQ VSDFH KHDWLQJ DSSOLFDWLRQVRQO\

Explosion Hazard

Temperature-Pressure Relief Valve must comply with ANSI Z21.22- CSA 4.4 and ASME code.

Properly sized temperature- pressure relief valve must be installed in opening provided.

Can result in overheating and excessive tank pressure.

Can cause serious injury or death.

7KLV ZDWHU KHDWHU LV SURYLGHG ZLWK D SURSHUO\ UDWHGVL]HG DQG FHUWL¿HG FRPELQDWLRQ WHPSHUDWXUH  SUHVVXUH 7 3  UHOLHI YDOYH E\ WKH PDQXIDFWXUHU 6HH 7HPSHUDWXUH3UHVVXUH 5HOLHI 9DOYH RQ SDJH  IRU LQIRUPDWLRQ RQ UHSODFHPHQW DQG RWKHU UHTXLUHPHQWV

CAUTION

Water Damage Hazard

Temperature-Pressure Relief Valve discharge pipe must terminate at adequate drain.

,QVWDOODGLVFKDUJHSLSHEHWZHHQWKH7 3YDOYHGLVFKDUJHRSHQLQJ DQG D VXLWDEOH ÀRRU GUDLQ 'R QRW FRQQHFW GLVFKDUJH SLSLQJ GLUHFWO\ WR WKH GUDLQ XQOHVV D ´  FP  DLU JDS LV SURYLGHG 7RSUHYHQWERGLO\LQMXU\KD]DUGWROLIHRUSURSHUW\GDPDJHWKH

UHOLHI YDOYH PXVW EH DOORZHG WR GLVFKDUJH ZDWHU LQ DGHTXDWH TXDQWLWLHVVKRXOGFLUFXPVWDQFHVGHPDQG,IWKHGLVFKDUJHSLSHLV QRWFRQQHFWHGWRDGUDLQRURWKHUVXLWDEOHPHDQVWKHZDWHUÀRZ PD\FDXVHSURSHUW\GDPDJH

T&P Valve Discharge Pipe Requirements:

‡ 6KDOOQRWEHVPDOOHULQVL]HWKDQWKHRXWOHWSLSHVL]HRIWKH

YDOYHRUKDYHDQ\UHGXFLQJFRXSOLQJVRURWKHUUHVWULFWLRQV ‡ 6KDOOQRWEHSOXJJHGRUEORFNHG

‡ 6KDOOQRWEHH[SRVHGWRIUHH]LQJWHPSHUDWXUHV

‡ 6KDOOEHRIPDWHULDOOLVWHGIRUKRWZDWHUGLVWULEXWLRQ

‡ 6KDOOEHLQVWDOOHGVRDVWRDOORZFRPSOHWHGUDLQDJHRIERWKWKH 7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHDQGWKHGLVFKDUJHSLSH

‡ 0XVWWHUPLQDWHDPD[LPXPRIVL[LQFKHVDERYHDÀRRU GUDLQRUH[WHUQDOWRWKHEXLOGLQJ,QFROGFOLPDWHVLWLV

UHFRPPHQGHGWKDWWKHGLVFKDUJHSLSHEHWHUPLQDWHGDWDQ

DGHTXDWHGUDLQLQVLGHWKHEXLOGLQJ

‡ 6KDOOQRWKDYHDQ\YDOYHRURWKHUREVWUXFWLRQEHWZHHQWKH

UHOLHIYDOYHDQGWKHGUDLQ

42

Page 42
Image 42
American Water Heater AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250 Water Line Connections Valve Discharge Pipe

AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250, Commercial Gas Water Heaters specifications

American Water Heater's Commercial Gas Water Heaters, particularly the AHCG/HCG3 60T 120 and AHCG3/HCG3 100T 250 models, stand out in the market for their impressive performance and reliable efficiency. Designed to meet the demanding needs of commercial applications, these gas water heaters provide an optimal solution for businesses requiring consistent hot water supply.

One of the main features of the AHCG/HCG3 series is its exceptional heat capacity. The models are engineered to deliver high recovery rates, ensuring that adequate hot water is available even during peak demand periods. The AHCG/HCG3 60T 120 can yield a robust output, ideal for smaller to medium-sized facilities, while the AHCG3/HCG3 100T 250 is designed for larger operations that require enhanced capacity.

These water heaters incorporate innovative technologies to maximize efficiency. The use of a high-efficiency burner system significantly reduces gas consumption, earning these models an Energy Factor rating that complies with modern energy standards. Additionally, the inclusion of a direct vent design allows for safe and efficient exhaust management, further promoting the energy-saving capabilities of these units.

The design of these commercial water heaters prioritizes durability and longevity. Constructed with heavy-duty components, including a corrosion-resistant water tank, these models are built to last, reducing the need for frequent replacements and maintenance. They also feature an advanced control system that monitors and adjusts the operation for optimal performance, enhancing user experience while decreasing operational costs.

Another notable characteristic of the AHCG/HCG3 series is their flexibility in installation. Both the 60T 120 and the 100T 250 models offer various venting options, which means they can easily fit into the existing infrastructure of many commercial facilities. This versatility facilitates a seamless integration process, saving time and resources during installation.

With a commitment to providing effective hot water solutions, American Water Heater continues to innovate, making the AHCG/HCG3 series a valuable addition to any commercial establishment. From restaurants to laundromats and beyond, these gas water heaters deliver reliable performance, ensuring that businesses can operate smoothly and efficiently.