4 INCH CONCENTRIC TERMINATION INSTALLATION

 

 

 

INTAKE AIR CONNECTION

INTAKE AIR PIPE

 

 

 

3 INCH PVC

 

VENT PIPE

 

 

 

 

3” x 3” x 4”

 

 

 

 

 

Y FITTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:KHQLQVWDOOLQJLQFKLQWDNHDLUDQGYHQWSLSHFRQQHFWWKH

SLSLQJWRWKHFRQFHQWULFWHUPLQDWLRQXVLQJ¿HOGVXSSOLHG[  UHGXFHU FRXSOLQJV DQG VKRUW VHFWLRQV RI  LQFK SLSH  LQFKHVRUOHVV SLSH&HPHQWDOO¿WWLQJVDQGSLSHLQSODFH

 5HWXUQWR'LUHFW9HQW,QVWDOODWLRQRQSDJHWRFRPSOHWHWKH

LQVWDOODWLRQ RI WKH LQWDNH DLU DQG YHQW SLSLQJ EHWZHHQ WKH FRQFHQWULFWHUPLQDWLRQDQGWKHZDWHUKHDWHU

VENT CONNECTION - 3 INCH PVC

VENT CAP

VENT PIPE IS 2 1/2 INCH SDR-26 PIPE SUPPLIED LENGTH 37 INCHES (94 cm)

MAXIMUM ALLOWABLE LENGTH 73 INCHES (185 cm) MINIMUM ALLOWABLE LENGTH 25 INCHES (64 cm)

INTAKE AIR PIPE IS 4 INCH SDR-26 PIPE SUPPLIED LENGTH 24 INCHES (60 cm)

MAXIMUM ALLOWABLE LENGTH 60 INCHES (152 cm) MINIMUM ALLOWABLE LENGTH 12 INCHES (30 cm)

INTAKE AIR PIPE

Y FITTING ASSEMBLY

VENT CAP

VENT PIPE ASSEMBLY

COMBUSTION

AIR

ROOF FLASHING (field supplied)

VENT

MAINTAIN 12” (30 cm)

 

 

 

 

 

 

 

18” (45 cm) FOR CANADA

 

 

 

 

 

 

 

MINIMUM CLEARANCE

 

 

 

 

 

 

 

ABOVE HIGHEST ANTICIPATED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SNOW LEVEL. MAXIMUM OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24” (60 cm) ABOVE ROOF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STRAP (field supplied)

NOTE: SECURING STRAP

MUST BE FIELD INSTALLED

TO PREVENT MOVEMENT

OF TERMINATION KIT

4 INCH CONCENTRIC TERMINATION KIT

FOUR PIECE KIT - FIELD ASSEMBLY REQUIRED

Figure 29

$VVHPEOHDQGLQVWDOOWKHLQFKFRQFHQWULFWHUPLQDWLRQ5HIHUWR )LJXUH)LJXUHDQG)LJXUHIRUWKHVHLQVWUXFWLRQV

 &HPHQWWKH<¿WWLQJWRWKHODUJHUGLDPHWHULQWDNHDLUSLSH  6OLGHWKHLQWDNHDLUSLSHDQG<¿WWLQJDVVHPEO\IURPLQVLGHWKH

VENT

INTAKE

PIPE

AIR PIPE

4 INCH CONCENTRIC TERMINATION

VERTICAL INSTALLATION

Figure 30

EXLOGLQJWKURXJKWKHKROHFXWIRUWKHWHUPLQDWLRQLQWKHURRI RU VLGHZDOO (QVXUH QR IRUHLJQ PDWHULDOV VXFK DV LQVXODWLRQ DFFXPXODWHLQVLGHWKHDVVHPEO\

 6HFXUHWKHLQWDNHDLU<¿WWLQJDVVHPEO\XVLQJ¿HOGVXSSOLHG

PHWDOVWUDSSLQJRUHTXLYDOHQWVXSSRUWPDWHULDOV

 2Q LQVWDOODWLRQV LQVWDOOHG WKURXJK WKH URRI VOLGH D ¿HOG VXSSOLHGSOXPELQJERRWRUURRIÀDVKLQJRYHUWKHLQWDNHDLU< ¿WWLQJDVVHPEO\DQGVHFXUHLWWRWKHURRI

 6HDODURXQGWKHSOXPELQJERRWRUURRIÀDVKLQJ

 &HPHQWWKHYHQWFDSRQWRWKHYHQWSLSH$OWHUQDWHO\D¿HOG VXSSOLHGVWDLQOHVVVWHHOVFUHZPD\EHXVHGWRVHFXUHWKH

FRPSRQHQWVWRJHWKHUZKHQ¿HOGGLVDVVHPEO\LVGHVLUHGIRU FOHDQLQJ$SLORWKROHPXVWEHGULOOHGIRUWKHVFUHZWRSUHYHQW GDPDJHFUDFNLQJRIWKHYHQWFDSDQGRUYHQWSLSH

 ,QVWDOOWKHYHQWFDSYHQWSLSHDVVHPEO\LQWRWKHLQWDNHDLU<

NOTE: SECURING STRAP MUST BE FIELD INSTALLED TO PREVENT MOVEMENT OF TERMINATION KIT IN SIDEWALL.

VENT

STRAP

PIPE

(field supplied)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTAKE

AIR PIPE

COMBUSTION

AIR

VENT

1 INCH

MAXIMUM

¿WWLQJDVVHPEO\(QVXUHVPDOOGLDPHWHUYHQWSLSHLVFHPHQWHG

DQGERWWRPHGLQWKH<¿WWLQJ

 :KHQ LQVWDOOLQJ  LQFK LQWDNH DLU DQG YHQW SLSLQJ FRQQHFW DQG FHPHQW WKH SLSH GLUHFWO\ WR WKH FRQFHQWULF WHUPLQDWLRQ

4 INCH CONCENTRIC TERMINATION

SIDEWALL INSTALLATION

Figure 31

31

Page 31
Image 31
American Water Heater Commercial Gas Water Heaters instruction manual Inch Concentric Termination Installation

AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250, Commercial Gas Water Heaters specifications

American Water Heater's Commercial Gas Water Heaters, particularly the AHCG/HCG3 60T 120 and AHCG3/HCG3 100T 250 models, stand out in the market for their impressive performance and reliable efficiency. Designed to meet the demanding needs of commercial applications, these gas water heaters provide an optimal solution for businesses requiring consistent hot water supply.

One of the main features of the AHCG/HCG3 series is its exceptional heat capacity. The models are engineered to deliver high recovery rates, ensuring that adequate hot water is available even during peak demand periods. The AHCG/HCG3 60T 120 can yield a robust output, ideal for smaller to medium-sized facilities, while the AHCG3/HCG3 100T 250 is designed for larger operations that require enhanced capacity.

These water heaters incorporate innovative technologies to maximize efficiency. The use of a high-efficiency burner system significantly reduces gas consumption, earning these models an Energy Factor rating that complies with modern energy standards. Additionally, the inclusion of a direct vent design allows for safe and efficient exhaust management, further promoting the energy-saving capabilities of these units.

The design of these commercial water heaters prioritizes durability and longevity. Constructed with heavy-duty components, including a corrosion-resistant water tank, these models are built to last, reducing the need for frequent replacements and maintenance. They also feature an advanced control system that monitors and adjusts the operation for optimal performance, enhancing user experience while decreasing operational costs.

Another notable characteristic of the AHCG/HCG3 series is their flexibility in installation. Both the 60T 120 and the 100T 250 models offer various venting options, which means they can easily fit into the existing infrastructure of many commercial facilities. This versatility facilitates a seamless integration process, saving time and resources during installation.

With a commitment to providing effective hot water solutions, American Water Heater continues to innovate, making the AHCG/HCG3 series a valuable addition to any commercial establishment. From restaurants to laundromats and beyond, these gas water heaters deliver reliable performance, ensuring that businesses can operate smoothly and efficiently.