TEMPERATURE-PRESSURE RELIEF VALVE

Explosion Hazard

Temperature-Pressure Relief Valve must comply with ANSI Z21.22- CSA 4.4 and ASME code.

Properly sized temperature- pressure relief valve must be installed in opening provided.

Can result in overheating and excessive tank pressure.

Can cause serious injury or death.

7KLV ZDWHU KHDWHU LV SURYLGHG ZLWK D SURSHUO\ UDWHGVL]HG DQG FHUWL¿HG FRPELQDWLRQ 7HPSHUDWXUH3UHVVXUH 5HOLHI 9DOYH 7 3 YDOYH E\WKHPDQXIDFWXUHU7KHYDOYHLVFHUWL¿HGE\DQDWLRQDOO\

UHFRJQL]HGWHVWLQJODERUDWRU\WKDWPDLQWDLQVSHULRGLFLQVSHFWLRQ RI SURGXFWLRQ RI OLVWHG HTXLSPHQW RI PDWHULDOV DV PHHWLQJ WKH UHTXLUHPHQWV IRU 5HOLHI 9DOYHV IRU +RW :DWHU 6XSSO\ 6\VWHPV $16,=‡&6$DQGWKHFRGHUHTXLUHPHQWVRI$60(

,I UHSODFHG WKH QHZ 7 3 YDOYH PXVW PHHW WKH UHTXLUHPHQWV RI ORFDO FRGHV EXW QRW OHVV WKDQ D FRPELQDWLRQ 7HPSHUDWXUH 3UHVVXUH 5HOLHI 9DOYH UDWHGVL]HG DQG FHUWL¿HG DV LQGLFDWHG LQ WKH DERYH SDUDJUDSK 7KH QHZ YDOYH PXVW EH PDUNHG ZLWK D PD[LPXP VHW SUHVVXUH QRW WR H[FHHG WKH PDUNHG K\GURVWDWLF ZRUNLQJSUHVVXUHRIWKHZDWHUKHDWHU SVL N3D DQG DGLVFKDUJHFDSDFLW\QRWOHVVWKDQWKHZDWHUKHDWHU%WXKURUN: LQSXWUDWHDVVKRZQRQWKHZDWHUKHDWHU¶VPRGHOUDWLQJODEHO

NOTE:,QDGGLWLRQWRWKHIDFWRU\LQVWDOOHG7HPSHUDWXUH3UHVVXUH 5HOLHI9DOYHRQWKHZDWHUKHDWHUHDFKUHPRWHVWRUDJHWDQNWKDW PD\EHLQVWDOOHGDQGSLSHGWRDZDWHUKHDWLQJDSSOLDQFHPXVWDOVR KDYHLWVRZQSURSHUO\VL]HGUDWHGDQGDSSURYHG7HPSHUDWXUH 3UHVVXUH 5HOLHI 9DOYH LQVWDOOHG &DOO WKH WROO IUHH WHFKQLFDO VXSSRUWSKRQHQXPEHUOLVWHGRQWKHEDFNFRYHURIWKLVPDQXDO IRUWHFKQLFDODVVLVWDQFHLQVL]LQJD7HPSHUDWXUH3UHVVXUH5HOLHI 9DOYHIRUUHPRWHVWRUDJHWDQNV

)RUVDIHRSHUDWLRQRIWKHZDWHUKHDWHUWKH7HPSHUDWXUH3UHVVXUH

5HOLHI9DOYHPXVWQRWEHUHPRYHGIURPLWVGHVLJQDWHGRSHQLQJ QRU SOXJJHG 7KH 7HPSHUDWXUH3UHVVXUH 5HOLHI 9DOYH PXVW EH LQVWDOOHGGLUHFWO\LQWRWKH¿WWLQJRIWKHZDWHUKHDWHUGHVLJQHGIRUWKH UHOLHIYDOYH,QVWDOOGLVFKDUJHSLSLQJVRWKDWDQ\GLVFKDUJHZLOOH[LW WKHSLSHZLWKLQLQFKHV FP DERYHDQDGHTXDWHÀRRUGUDLQ RUH[WHUQDOWRWKHEXLOGLQJ,QFROGFOLPDWHVLWLVUHFRPPHQGHG WKDWLWEHWHUPLQDWHGDWDQDGHTXDWHGUDLQLQVLGHWKHEXLOGLQJ%H FHUWDLQWKDWQRFRQWDFWLVPDGHZLWKDQ\OLYHHOHFWULFDOSDUW7KH GLVFKDUJHRSHQLQJPXVWQRWEHEORFNHGRUUHGXFHGLQVL]HXQGHU DQ\FLUFXPVWDQFHV([FHVVLYHOHQJWKRYHUIHHW P RU

XVHRIPRUHWKDQIRXUHOERZVFDQFDXVHUHVWULFWLRQDQGUHGXFH

WKHGLVFKDUJHFDSDFLW\RIWKHYDOYH

1R YDOYH RU RWKHU REVWUXFWLRQ LV WR EH SODFHG EHWZHHQ WKH 7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHDQGWKHWDQN'RQRWFRQQHFW GLVFKDUJH SLSLQJ GLUHFWO\ WR WKH GUDLQ XQOHVV D ´  FP  DLU JDS LV SURYLGHG 7R SUHYHQW ERGLO\ LQMXU\ KD]DUG WR OLIH RU SURSHUW\GDPDJHWKHUHOLHIYDOYHPXVWEHDOORZHGWRGLVFKDUJH

ZDWHU LQ DGHTXDWH TXDQWLWLHV VKRXOG FLUFXPVWDQFHV GHPDQG ,I WKHGLVFKDUJHSLSHLVQRWFRQQHFWHGWRDGUDLQRURWKHUVXLWDEOH PHDQVWKHZDWHUÀRZPD\FDXVHSURSHUW\GDPDJH

CAUTION

Water Damage Hazard

Temperature-Pressure Relief Valve discharge pipe must terminate at adequate drain.

T&P Valve Discharge Pipe Requirements:

‡ 6KDOOQRWEHVPDOOHULQVL]HWKDQWKHRXWOHWSLSHVL]HRIWKH

YDOYHRUKDYHDQ\UHGXFLQJFRXSOLQJVRURWKHUUHVWULFWLRQV ‡ 6KDOOQRWEHSOXJJHGRUEORFNHG

‡ 6KDOOQRWEHH[SRVHGWRIUHH]LQJWHPSHUDWXUHV

‡ 6KDOOEHRIPDWHULDOOLVWHGIRUKRWZDWHUGLVWULEXWLRQ

‡ 6KDOOEHLQVWDOOHGVRDVWRDOORZFRPSOHWHGUDLQDJHRIERWKWKH 7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHDQGWKHGLVFKDUJHSLSH

‡ 0XVWWHUPLQDWHDPD[LPXPRIVL[LQFKHVDERYHDÀRRUGUDLQ RUH[WHUQDOWRWKHEXLOGLQJ,QFROGFOLPDWHVLWLVUHFRPPHQGHG

WKDWWKHGLVFKDUJHSLSHEHWHUPLQDWHGDWDQDGHTXDWHGUDLQ

LQVLGHWKHEXLOGLQJ

‡ 6KDOO QRW KDYH DQ\ YDOYH RU RWKHU REVWUXFWLRQ EHWZHHQ WKH

UHOLHIYDOYHDQGWKHGUDLQ

Burn hazard.

Hot water discharge.

Keep clear of Temperature- Pressure Relief Valve discharge outlet.

The Temperature-Pressure Relief Valve must be manually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

NOTE: The purpose of a Temperature-Pressure Relief Valve is

WRSUHYHQWH[FHVVLYHWHPSHUDWXUHVDQGSUHVVXUHVLQWKHVWRUDJH WDQN 7KH 7 3 YDOYH LV QRW LQWHQGHG IRU WKH FRQVWDQW UHOLHI RI WKHUPDOH[SDQVLRQ$SURSHUO\VL]HGWKHUPDOH[SDQVLRQWDQNPXVW EHLQVWDOOHGRQDOOFORVHGV\VWHPVWRFRQWUROWKHUPDOH[SDQVLRQ VHH&ORVHG:DWHU6\VWHPVDQG7KHUPDO([SDQVLRQRQSDJH

,I \RX GR QRW XQGHUVWDQG WKHVH LQVWUXFWLRQV RU KDYH DQ\ TXHVWLRQVUHJDUGLQJWKH7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHFDOO WKHWROOIUHHQXPEHUOLVWHGRQWKHEDFNFRYHURIWKLVPDQXDOIRU

WHFKQLFDODVVLVWDQFH

16

Page 16
Image 16
American Water Heater AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250 instruction manual TEMPERATURE-PRESSURE Relief Valve

AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250, Commercial Gas Water Heaters specifications

American Water Heater's Commercial Gas Water Heaters, particularly the AHCG/HCG3 60T 120 and AHCG3/HCG3 100T 250 models, stand out in the market for their impressive performance and reliable efficiency. Designed to meet the demanding needs of commercial applications, these gas water heaters provide an optimal solution for businesses requiring consistent hot water supply.

One of the main features of the AHCG/HCG3 series is its exceptional heat capacity. The models are engineered to deliver high recovery rates, ensuring that adequate hot water is available even during peak demand periods. The AHCG/HCG3 60T 120 can yield a robust output, ideal for smaller to medium-sized facilities, while the AHCG3/HCG3 100T 250 is designed for larger operations that require enhanced capacity.

These water heaters incorporate innovative technologies to maximize efficiency. The use of a high-efficiency burner system significantly reduces gas consumption, earning these models an Energy Factor rating that complies with modern energy standards. Additionally, the inclusion of a direct vent design allows for safe and efficient exhaust management, further promoting the energy-saving capabilities of these units.

The design of these commercial water heaters prioritizes durability and longevity. Constructed with heavy-duty components, including a corrosion-resistant water tank, these models are built to last, reducing the need for frequent replacements and maintenance. They also feature an advanced control system that monitors and adjusts the operation for optimal performance, enhancing user experience while decreasing operational costs.

Another notable characteristic of the AHCG/HCG3 series is their flexibility in installation. Both the 60T 120 and the 100T 250 models offer various venting options, which means they can easily fit into the existing infrastructure of many commercial facilities. This versatility facilitates a seamless integration process, saving time and resources during installation.

With a commitment to providing effective hot water solutions, American Water Heater continues to innovate, making the AHCG/HCG3 series a valuable addition to any commercial establishment. From restaurants to laundromats and beyond, these gas water heaters deliver reliable performance, ensuring that businesses can operate smoothly and efficiently.