Installation
8 Mio Modero Device Family
Setting The AxLink Device Number
1. If connected, disconnect the power supply.
2. Locate the 8-position Device DIP switch on the rear panel.(FIG.5).
3. Set the DIP switch according to the switch values shown below.
The device number is set by the total value of DIP switch positions that are ON (up).
As an example, the DIP switch in FIG.5 defines device number 129 (1+128=129).
If you later change the device number, remove and reconnect the AxLink power connector to enter the
new device number into memory.
Wiring
The Mio Modero uses a four-pin mini AxLink connector for power and data.
Preparing captive wires
You will need a wire stripper, and flat-blade screwdriver to prepare and connect the captive wires.
1. Strip 0.25 inch (6.35 mm) of wire insulation off all wires.
2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and
connector types described in this section.
3. Turn the flat-head screws clockwise to secure the wires in the connector.
Switch12345678
Value 1 2 4 8 16 32 64 128
FIG. 5 Example Device DIP Switch set to 129
AMX has created Dip Switch2 to assist in calculating dip switch position values.
Download the program Dip Switch2 from www.amx.com for free.
Do not connect power to the Mio Modero until the wiring is complete.
Do not over-torque the screws; doing so can bend the seating pins and damage the
connector.