Anritsu S113C, S332C, S114C, S331C manual Range Errors, ERRORD2

Models: S113C S332C S114C S331C

1 95
Download 95 pages 26 Kb
Page 36
Image 36

Chapter 2 Functions and Operations

Range Errors

A listing of Range Error messages is given in Table 2-3.

Table 2-3.Range Error Messages (1 of 2)

Error Message

Description

RANGE

The start (F1) frequency is greater than the stop (F2) frequency.

ERROR:F1 > F2

 

 

 

RANGE

The start (D1) distance is greater than the stop (D2) distance.

ERROR:D1 > D2

 

 

 

RANGE

The stop distance (D2) exceeds the maximum unaliased range. This

ERROR:D2 >

range is determined by the frequency span, number of points,

DMax=xx.x ft (m)

and relative propagation velocity:

 

MaximumUnaliased Range ￿

(1.5 ￿ 108) (dp ￿ 1) (V f )

 

F2 ￿ F1

 

 

 

 

Where: dp is the number of data points (130, 259, or 517)

 

Vf is the relative propagation velocity

 

F2 is the stop frequency in Hz

 

F1 is the start frequency in Hz

 

Maximum Unaliased Range is in meters

RANGE ERROR:

The SWR scale parameter top value is less than or equal to its bottom

TOP<=BOTTOM

value.

RANGE ERROR:

The RL scale parameter top value is greater than or equal to its bottom

TOP>=BOTTOM

value.

CAL

A complete open, short, and load calibration must be performed bef-

INCOMPLETE

ore calibration can be turned on.

DIST REQUIRES

Valid distance to fault plots require a non-zero frequency span.

F1 < F2

 

 

 

DIST REQUIRES

Distance-to-fault measurements cannot be performed with CAL OFF.

CAL

 

 

 

NO STORED

Attempting to recall a display from a location that has not been previ-

SWEEP AT THIS

ously written to. That is, the location does not contain stored sweep.

LOCATION

 

 

 

USE OPTIONS

Attempting to print a display with no printer selected. Select a printer,

MENU TO

then retry.

SELECT A

 

 

 

PRINTER

 

 

 

DISTANCE AND

DTF measurements only display RL or SWR versus distance.

CABLE

 

 

 

INSERTION LOSS

 

 

 

MODE ARE

 

 

 

INCOMPATIBLE

 

 

 

 

 

 

 

2-21

Page 36
Image 36
Anritsu S113C, S332C, S114C, S331C manual Range Errors, ERRORD2

S113C, S332C, S114C, S331C specifications

Anritsu, a leader in test and measurement solutions, offers a range of handheld tools that cater to the needs of professionals in the RF and microwave industries. Among these tools are the Anritsu S331C, S114C, S332C, and S113C, each designed with unique features and technologies that make them suitable for various applications.

The Anritsu S331C is a Cable and Antenna Analyzer that is particularly valued for its accuracy and ease of use. It operates within a frequency range of 3 MHz to 4 GHz, making it applicable for both wireless and microwave communication systems. One of its standout features is the built-in Time Domain Reflectometry (TDR) function, which allows technicians to pinpoint faults in cables quickly. The S331C's intuitive touch-screen interface ensures seamless operation, while its lightweight design allows for portability in the field.

On the other hand, the Anritsu S114C is a versatile handheld RF power meter that can measure a wide range of power levels and frequencies. Its exceptional measurement accuracy and broad dynamic range make it suitable for various applications, from network testing to maintenance. It supports both peak and average power measurements, providing users with the flexibility to adapt to different testing scenarios. The S114C also features a memory function that allows users to store and recall measurement data easily.

The S332C model is designed for more advanced applications, offering vector network analysis capabilities. Operating within a frequency range of 5 kHz to 4 GHz, it is used for characterizing components such as filters, amplifiers, and cables. The S332C features a high-resolution display and supports automated measurements, making it a powerful tool for engineers involved in the design and validation of RF components.

Lastly, the Anritsu S113C is an excellent choice for professionals requiring a compact and efficient solution for insertion loss and return loss measurements. This analyzer covers a frequency range of 5 kHz to 4 GHz and is especially suited for testing antennas and RF components. The S113C's lightweight design, combined with its user-friendly interface, allows operators to conduct measurements easily in various environments, ensuring high performance and reliability.

In summary, the Anritsu S331C, S114C, S332C, and S113C represent a comprehensive suite of handheld analyzers that cater to diverse needs in the RF and microwave sectors. With features like TDR function, RF power measurements, vector network analysis, and a focus on portability, these instruments are essential tools for professionals looking to enhance their testing capabilities and ensure high-quality network performance.