![](/images/new-backgrounds/1000866/866125x1.webp)
Chapter 4 Cable & Antenna Measurements
Antenna Subsystem Return Loss Test
Antenna Subsystem return loss measurement verifies the performance of the transmit and receive antennas. This measurement can be used to analyze the performance of the antenna before installation. The antenna can be tested for the entire frequency band, or tested to a specific frequency range. Transmit and receive frequency measurements are conducted sep- arately. The following steps explain how to measure the antenna loss in return loss mode.
Required Equipment
Site Master Model S113C, S114C, S331C, or S332C
Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50LF
Precision Load, Anritsu SM/PL
Test Port Extension Cable, Anritsu
Optional
Anritsu InstaCal Module, ICN50
Device Under Test
Antenna Sub Assembly
Procedure
Step 1. Press the MODE key.
Step 2. Select
ENTER.
Step 3. Connect the Test Port Extension cable to the RF port and calibrate the Site Mas- ter as described on page
Step 4. Press SAVE SETUP and save the calibration set up (page
Step 5. Connect the Device Under Test to the Site Master phase stable Test Port Exten- sion cable.
Step 6. Press the MARKER key.
Step 7. Set markers M1 and M2 to the desired frequency.
Step 8. Record the lowest return loss over the specified frequency.
Step 9. Press SAVE DISPLAY (page