Problem | Possible Cause | Corrective Action | |
|
|
| |
Steam from generator is | Restrictor tube or generator tubes are | Clean restrictor tube and/or generator | |
reduced compared to former | clogged. | tubes. | |
operation. |
|
| |
Flooding condition. | Allow 20 minutes for excess water to evapo- | ||
| |||
|
| rate and generator to recover to 375°F. | |
|
|
| |
| Insufficient preheat. | Allow excess water on the generator casting | |
|
| to evaporate and preheat 20 minutes before | |
|
| operating. DO NOT operate steamer during | |
|
| preheat cycle. | |
|
|
| |
| Filters require cleaning. | See page 14. | |
|
|
| |
| Control board setpoint temperature | Surface temperature of the casting should | |
| too low. | be between 375°- 425° F (191°- 218°C) | |
|
| when the red light on the control board | |
|
| turns off. If the temp is too low, contact | |
|
| maintenance or AJA Authorized Service | |
|
| Center. | |
| Heavy deposit buildup on the genera- | See maintenance procedure under Cleaning | |
| tor. | Generator. | |
|
|
| |
Unit becomes flooded or | Incorrect water pressure. | *(Regulated units only.) Set water pressure | |
always steaming. Power | |||
| to 20 psi (138 kPa). | ||
ON, solenoid makes a chat- |
| ||
|
| ||
| May need to cleaned or replaced. Contact | ||
tering noise. | Solenoid valve inoperable or particles | ||
or | in the valve. | maintenance or AJA Authorized Service | |
| Center. | ||
|
| ||
Unit floods overnight. Power |
|
| |
Control board is not programmed | Verify programming as described in the | ||
OFF. | |||
properly. | Programming section. | ||
| |||
|
|
| |
| Control board is inoperable. | Contact maintenance or AJA Authorized | |
|
| Service Center. | |
|
|
| |
Water leaking in the | Pin hole leak in the hoses. | Replace the hoses. | |
electrical housing. |
|
| |
Inlet tube or restrictor tube is loose. | Tighten the loose fittings. | ||
| |||
|
|
| |
| Generator tube is loose or damaged. | Tighten loose fittings or contact mainte- | |
|
| nance or AJA Authorized Service Center. | |
|
|
| |
|
|
|