Antunes, AJ MS-355, MS-250/255 Miracle Steamer, Problem, Possible Cause, Corrective Action

Models: MS-250/255 MS-355

1 28
Download 28 pages 49.51 Kb
Page 18
Image 18
Manual background

A.J. Antunes & Co.

MIRACLE STEAMER

Problem

Possible Cause

Corrective Action

 

 

 

Unit heats up, pump or sole-

Programming.

See pages 8-10.

noid valve works with the

 

 

If Ready light does not light but the

Contact maintenance or AJA Authorized

momentary switch but will

unit steams regularly, the Ready light

Service Center.

not steam during timer

is inoperable.

 

cycles.

 

 

 

 

If the Ready light does light and the

Contact maintenance or AJA Authorized

 

unit does not steam, the control board

Service Center.

 

is inoperable.

 

 

 

 

 

*(Direct Feed Units) Quick-disconnect

Make sure the quick-disconnect and O-ring

 

not connected properly or inoperable.

are properly positioned and are not dam-

 

 

aged. Replace damaged parts.

 

 

 

 

Water volume adjustment is too low.

Adjust the water volume control. See

 

 

Calibration section of the manual.

 

 

 

 

Water filter clogged.

Remove and clean filter.

 

Inoperable solenoid or solenoid dam-

Make sure unit is connected to a cold water

 

age caused by connecting a hot

supply. Contact maintenance or AJA

 

water supply line.

Authorized Service Center.

 

 

 

 

Inoperable control board.

Contact maintenance or AJA Authorized

 

 

Service Center.

Steam coming out around

Wingnut is loose.

Tighten wingnut.

top covers or sides.

 

 

 

Generator cover damage.

Adjust or replace generator cover.

 

 

 

P/N 1010699 Rev. B

 

17

 

 

 

 

 

 

Page 18
Image 18
Antunes, AJ MS-355, MS-250/255 owner manual Miracle Steamer, Problem, Possible Cause, Corrective Action