E1618 | PS # Predictive | Power supply voltage is out of acceptable range; specified |
|
| power supply is improperly installed or faulty. |
|
|
|
E161C | PS # Input Lost | Power source for specified power supply is unavailable, or out |
|
| of acceptable range. |
|
|
|
E1620 | PS # Input Range | Power source for specified power supply is unavailable, or out |
|
| of acceptable range. |
|
|
|
E1624 | PS Redundancy | The power supply subsystem is no longer redundant. If the last |
|
| supply fails, the system will go down. |
|
|
|
E1710 | I/O Channel Chk | The system BIOS has reported an I/O channel check. |
|
|
|
E1711 | PCI PERR B## D## F## | The system BIOS has reported a PCI parity error on a |
| PCI PERR Slot # | component that resides in PCI configuration space at bus ##, |
|
| device ##, function ##. |
|
| The system BIOS has reported a PCI parity error on a |
|
| component that resides in the specified PCI slot. |
|
|
|
E1712 | PCI SERR B## D## F## | The system BIOS has reported a PCI system error on a |
| PCI SERR Slot # | component that resides in PCI configuration space at bus ##, |
|
| device ##, function ##. |
|
| The system BIOS has reported a PCI system error on a |
|
| component that resides in the specified slot. |
|
|
|
E1714 | Unknown Err | The system BIOS has determined that there has been an error in |
|
| the system, but is unable to determine its origin. |
|
|
|
E171F | PCIE Fatal Err B## | The system BIOS has reported a PCIe fatal error on a |
| D## F## | component that resides in PCI configuration space at bus ##, |
| PCIE Fatal Err Slot # | device ##, function ##. |
|
| The system BIOS has reported a PCIe fatal error on a |
|
| component that resides in the specified slot. |
|
|
|
E1810 | HDD ## Fault | The SAS subsystem has determined that hard drive ## has |
|
| experienced a fault. |
|
|
|
E1811 | HDD ## Rbld Abrt | The specified hard drive has experienced a rebuild abort. |
|
|
|
E1812 | HDD ## Removed | The specified hard drive has been removed from the system. |
|
|
|
E1913 | CPU & Firmware | The BMC firmware does not support the CPU. |
| Mismatch |
|
|
|
|
E1A11 | PCI Rsr Config | PCI risers are not configured correctly; some invalid |
|
| configurations may prevent the system from turning on. |
|
|
|
E1A12 | PCI Rsr Missing | One or all of the PCI risers are missing, preventing the system |
|
| from turning on. |
|
|
|
E1A14 | SAS Cable A | SAS cable A is missing or bad. |
|
|
|
E1A15 | SAS Cable B | SAS cable B is missing or bad. |
|
|
|
E2010 | No Memory | No memory is installed in the system. |
|
|
|
E2011 | Mem Config Err | Memory detected, but is not configurable. Error detected during |
|
| memory configuration. |
|
|
|
E2012 | Unusable Memory | Memory is configured, but not usable. Memory subsystem |
|
| failure. |
|
|
|
E2013 | Shadow BIOS Fail | The system BIOS failed to copy its flash image into memory. |
|
|
|
E2014 | CMOS Fail | CMOS failure. CMOS RAM not functioning properly. |
|
|
|
E2015 | DMA Controller | DMA controller failure. |
|
|
|
E2016 | Int Controller | Interrupt controller failure. |
|
|
|
22 | InfraStruXure Central Installation Manual |