Hard Drive Tests

When Server Diagnostics EFI starts, it performs a hardware existence test. Hard drives found during this test can be tested individually using hard drive tests.

Test

Estimated completion time

Description

Full Read

3 hours for a 1 TB drive

Performs a DMA full-read scan

 

 

at 1250 RPM. This checks the

 

 

entire hard drive for slow-read

 

 

failures.

 

 

This test is available for hard

 

 

drives, but not solid-state drives.

 

 

 

Abbreviated Read

2 minutes

Performs a DMA scan at 1250

 

 

RPM. This checks the first 10 GB

 

 

of the hard drive for slow-read

 

 

failures.

 

 

This test is available for hard

 

 

drives, but not solid-state drives.

 

 

 

Check SMART Status

1 second

Check the SMART status of

 

 

a hard drive.

 

 

This test is available for hard

 

 

drives, but not solid-state drives.

 

 

 

Memory Tests

Simple Memory Tests

In Server Diagnostics EFI, memory tests (simple, multicore, and extended) are grouped under Memory tests.

Note: The time required to complete memory tests correlates to the amount of memory being tested. These estimates are based on testing 8 GB of memory.

Test

Estimated completion time

Description

Address as Data

15 seconds

Tests memory using the

 

 

memory address as data.

 

 

 

Patterns

40 seconds

Tests memory using different

 

 

data patterns.

 

 

 

Marching Ones and Zeros

30 seconds

Tests memory by walking 1s and

 

 

0s up and down memory.

 

 

 

Knaizuk Hartmann

20 seconds

Tests memory using this

 

 

algorithm.

 

 

 

MOD3

1 minute

Tests memory using this

 

 

algorithm.

 

 

 

March U

3 minutes

Tests memory using Van de

 

 

Goor’s March U algorithm.

 

 

 

40

Appendix    Server Diagnostics Test Reference

Page 40
Image 40
Apple 3X108 manual Hard Drive Tests, Memory Tests