Troubleshooting
Regarding the indicator lamps (continued)
POWER | LAMP TEMP | Description | |
indicator | indicator indicator | ||
|
|
|
| There is a possibility that the interior portion | |
|
|
| has become heated. | |
|
|
| Please turn the power off, and allow the projector to | |
|
|
| cool down at least 20 minutes. After the projector has | |
Blinking |
|
| sufficiently cooled down, please make confirmation of | |
|
| the following items, and then turn the power on again. | ||
In Red | Turned | Lighting | ||
• Is there blockage of the air passage aperture? | ||||
or | ||||
off | In Red | • Is the air filter dirty? | ||
Lighting | ||||
|
| • Does the peripheral temperature exceed 35°C? | ||
In Red |
|
| ||
|
| • If the projector is used at an altitude of about 1600 m | ||
|
|
| ||
|
|
| (5250 feet) or higher, set ALTITUDE of the SERVICE | |
|
|
| item in the OPTION menu to HIGH (57). If the | |
|
|
| projector is used with a wrong setting, it may cause | |
|
|
| damage to the projector itself or the parts inside. |
|
| It is time to clean the air filter. |
|
| Please immediately turn the power off, and clean or |
Lighting | Simultaneous | change the air filter referring to the section Cleaning |
In Green | blinking in Red | and replacing the air filter. After cleaning or changing |
|
| the air filter, please be sure to reset the filter timer. |
|
| After the remedy, reset the power to ON. |
|
|
| There is a possibility that the interior portion | |
Lighting | Alternative | has become overcooled. | ||
Please use the unit within the usage temperature | ||||
In Green | blinking in Red | |||
parameters (5°C to 35°C). | ||||
|
|
| ||
|
|
| After the treatment, reset the power to ON. | |
|
|
|
| |
Blinking In |
|
| At least 1 Power ON schedule is saved to the | |
Green for | Turned | Turned | projector. | |
approx. 3 | off | off | Please refer to Schedule Settings in the Network | |
seconds. |
|
| Guide. |
NOTE • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH (57). Otherwise, set it to NORMAL.
101