Refrigerant Circuit Performance Charts (continued)
Refrigerant Circuit Performance Charts: A & B Voltage Models
Spa Condition: Water @ 104ºF & 45 GPM, Ent. Air: 80 ºF - 63% R.H.
Model | Discharge | Suction | Superheat | Subcooling | Water ∆T |
| Pressure | Pressure | ºF | ºF | ºF |
| PSIG | PSIG |
|
|
|
H/AT100”X”R | 307 | 85 | 10 | 25 | 3.9 |
|
|
|
|
|
|
H/AT120”X”R |
|
| (Data Pending) |
| |
|
|
|
|
|
|
Nominal UnitAmps byVoltageCode
A | B |
28 | (Pending) |
| |
|
|
Standard Condition: Water @ 80ºF & 45 GPM, Ent. Air: 80 ºF - 63% R.H.
Model | Discharge | Suction | Superheat | Subcooling | Water ∆T |
| Pressure | Pressure | ºF | ºF | ºF |
| PSIG | PSIG |
|
|
|
H/AT100”X”R | 224 | 81 | 11 | 20 | 4.0 |
H/AT120”X”R | 205 | 74 | 16 | 18 | 4.6 |
|
|
|
|
|
|
Nominal UnitAmps byVoltageCode
A | B |
23 | (Pending) |
25 | |
|
|
Low Condition: Water @ 80ºF & 45 GPM, Ent. Air: 50 ºF - 63% R.H.
Model | Discharge | Suction | Superheat | Subcooling | Water ∆T |
| Pressure | Pressure | ºF | ºF | ºF |
| PSIG | PSIG |
|
|
|
H/AT100”X”R | 218 | 49 | 8 | 31 | 2.8 |
H/AT120”X”R | 212 | 44 | 9 | 26 | 3 |
|
|
|
|
|
|
Nominal UnitAmps byVoltageCode
A | B |
22 | (Pending) |
24 | |
|
|
High R.H. Condition: Water @ 80ºF & 45 GPM, Ent. Air: 80 ºF - 80% R.H.
Model | Discharge | Suction | Superheat | Subcooling | Water ∆T |
| Pressure | Pressure | ºF | ºF | ºF |
| PSIG | PSIG |
|
|
|
H/AT100”X”R | 227 | 89 | 14 | 18 | 4.4 |
H/AT120”X”R | 208 | 80 | 17 | 19 | 4.9 |
|
|
|
|
|
|
Nominal UnitAmps byVoltageCode
A | B |
23 | (Pending) |
26 | |
|
|
Cooling Condition: Water @ 85ºF & 45 GPM, Ent. Air: 95 ºF - 34% R.H.
Model | Discharge | Suction | Superheat | Subcooling | Water ∆T |
| Pressure | Pressure | ºF | ºF | ºF |
| PSIG | PSIG |
|
|
|
H/AT100”X”R | 276 | 93 | 14 | 1 | 2.5 |
H/AT120”X”R | 280 | 82 | 16 | 6 | 3 |
|
|
|
|
|
|
Nominal UnitAmps byVoltageCode
A | B |
27 | (Pending) |
32 | |
|
|
39