1.4Environmental Standards

Table 1.2: Environmental Standards

Environmental Operational Parameters

Operation

0° C to 50° C

 

-10° C to 55° C*

Temperature

 

 

* Battery mode:

 

 

 

0°C @ 50% Battery capacity.

 

 

 

* Adapter mode: Any

 

( MIL-STD 810F Methods 501.4 and 502.4 )

 

 

 

Storage Temperature

-20° C to 60° C

 

-40° C to 75° C

 

( MIL-STD 810F Methods 501.4 and 502.4 )

 

 

 

Thermal Shock

1.5° C < 5° C / minute over 0° C

 

1.5°C < 5° C / minute over -10° C

 

to 50° C verified during

 

to 55° C verified during

 

MILSTD810F testing

 

MILSTD810F testing

Operational Humidity

0% to 95% non-condensing MIL-STD810F Method 507.4

 

 

Storage Humidity

0% to 95% non-condensing MIL-STD810F Method 507.4

 

 

 

IP Rating

IP-54

 

 

 

Drop

3 foot high free drop survival limit, (test surface: concrete, base unit

 

only). According to MIL-STD-810F, Method 516.5

Shock and Pressure

 

 

 

Mechanical Shock

20g, 11ms, Terminal sawtooth, operating.

 

40g, 11ms, Terminal sawtooth, non-operating

 

MIL-STD-810F method 516.5

 

Vibration

- Operation

 

 

By CF: MIL-STD 810F Methods 514.5C-3

 

By HDD: MIL-STD 810F Methods 514.5C-1

 

- Non-operation

 

 

0.04g^2/Hz, 20Hz - 1000Hz, -6dB/octave 1000Hz - 2000Hz,

 

MIL- STD-810F method 514.5C-17

Low Pressure

-15,000 ft.: in accordance with MIL-STD810F; Method 500.4, Proce-

 

dure I

 

Agency Approvals

 

 

 

EMC

- EN55022 Class B

 

 

- EN55011 Class A

 

 

- FCC Part15 Class B

 

 

- DOC Class B

 

EMS

- Contact: 4Kv/ Air: 8Kv, EN55024

 

 

 

 

Safety

- UL / cUL, UL60950-1

 

 

- CB, IEC/EN60950-1

 

MARS-3100R/S User Manual