A.2 Specifications

Input Characteristics

Input Voltage Range

Min

Nom

Max

Range 1

90V

115V

135V

Range 2

180V

230V

265V

 

 

 

Input Frequency Range

47 Hz to 63 Hz

 

 

 

 

Maximum Input ac Current

9A max at 115Vac

 

 

5A max. at 230Vac, maximum load

 

 

 

Inrush Current

70A max. at 115Vac,

 

 

full load cold start at 25°C

 

 

 

 

Efficiency

68% min. at nominal input,

 

 

maximum load

 

 

 

 

 

Output Characteristics

Output

Load Range

Regulation

Ripple

Voltage

Min

Max

Min

Max

Max

+5V

1.5A

25.0A

-5%

+5%

50mVp-p

 

 

 

 

 

 

+12V

0.2A

8.0A

-5%

+5%

120mVp-p

 

 

 

 

 

 

-12V

0A

0.8A

-10%

+10%

150mVp-p

 

 

 

 

 

 

-5V

0A

0.5A

-5%

+5%

100mVp-p

 

 

 

 

 

 

+5Vsb

0A

2.0A

-5%

+5%

100mVp-p

 

 

 

 

 

 

+3V3

0A

14.0A

-5%

+5%

50mVp-p

 

 

 

 

 

 

Over-Voltage Protection (OVP)

Output Voltage Maximum Voltage

+5V6.5V

+12V15.6V

+3.3V4.3V

NOTE

The power supply will shut down and latch off for shorting +5V, +12V, -12V, -5V, or +3.3V. By shorting +5Vsb, the power supply can latch down or automatically recover when the fault condition is removed.