IV. Hardware Setup
• 4-2. Rear Cooling Fan Control Board
The rear fans are controlled and monitored by a control board. The fan control board requires power input from the power supply which allows the individual fans to obtain their power when connected to the control board. The control board also sends fan status information to the LEDs located on the front of the server and to the ASMA software. The fan control board’s cable connections are shown below.
Fan
Fan Power
Connectors
Reserved |
|
|
| Power Input |
|
| |||
Connector |
| Connector |
Fan Status Signal
Fan Control
Connector
Settings
Reserved
Fan Connectors
Rear Cooling Fan Control Board Settings
The rear fan control board has DIP switches to allow controlling the control board status and the number of fans.
DIP Switch SET1 |
| Fan Control Board Setting | |||||
ON (momentarily) | Reset Control Board | ||||||
|
|
|
|
|
|
|
|
OFF |
|
|
| Normal (Default) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| SET2 | SET3 |
| SET4 | Number of Fans |
| |
| ON | ON |
| ON | 1 |
| |
|
|
|
|
|
|
| |
| ON | ON |
| OFF | 2 (Default) |
| |
|
|
|
|
|
|
| |
| ON | OFF |
| ON | 3 |
| |
|
|
|
|
|
|
| |
| ON | OFF |
| OFF | 4 |
| |
|
|
|
|
|
|
| |
| OFF | ON |
| ON | 5 |
| |
|
|
|
|
|
|
| |
| OFF | ON |
| OFF | 6 |
| |
|
|
|
|
|
|
| |
| OFF | OFF |
| ON | 7 |
| |
|
|
|
|
|
|
| |
| OFF | OFF |
| OFF | 8 |
| |
|
|
|
|
|
|
|
|
Hardware Setup | Rear Fans |
IV. |
|
|
|