Setup Hardware .IV
Info Supply Power
IV. Hardware Setup
Power Supply Information
Output Voltage Regulation, Ripple, and Noise
Output Voltage Limits (Vdc) | Ripple/Noise | |||||
|
|
|
|
|
|
|
Output | Min |
| Nom |
| Max | Maximum |
|
|
|
|
|
|
|
1 | 3.17V |
| 3.30V |
| 3.46V | |
|
|
|
|
|
|
|
2 | 4.80V |
| 5.00V |
| 5.25V | |
3 | 11.40V | 12.00V | 12.60V | |||
4 |
| |||||
5 | ||||||
6 | 4.75V |
| 5.00V |
| 5.25V | |
Output Current Capacity |
|
|
| |||
|
|
|
|
|
|
|
Output | Nom (Vdc) | Max (A) | Min (A) |
| ||
|
|
|
|
|
|
|
1 | 3.3V |
| *20.0 |
| 1.0 |
|
|
|
|
|
|
|
|
2 | 5.0V |
| *45.0 |
| 2.0 |
|
|
|
|
|
|
|
|
3 | 12.0V |
| 12.0 |
| 0.5 |
|
|
|
|
|
|
|
|
4 |
| 0.5 |
| 0.0 |
| |
|
|
|
|
|
|
|
5 |
| 0.5 |
| 0.0 |
| |
|
|
|
|
|
|
|
* Total output power for 3.3V and 5V combined shall be 210W
Input Voltage
Range | Min (V) | Nom (V) | Max (V) |
|
|
|
|
Range 1 | 90 | 120 | 137 |
|
|
|
|
Range 2 | 180 | 230 | 265 |
|
|
|
|
Safety
The power system meets all applicable clauses for UL 1950 2nd edition without D3 deviations. The power system passes all tests for CUL and TUV safety.
EMI
The power system, operating with resistive load, meets FCC class B and CISPR 22 class B conducted limits.
36 | AP 3000 Hardware Reference Guide |