IV. Hardware Setup

4-12. SCSI ID Setting

SCSI ID settings are made through DIP switches located on the SCSI board. The SCSI board has four dip switches to set the hard drive’s power-ON delay and SCSI ID.

SCSI ID Setting

 

IDSEL1

IDSEL0

 

Slot1

 

Slot2

 

Slot3A/3B

Slot4

Slot5A/5B

 

 

 

 

 

 

 

 

 

 

 

 

 

off

off

 

Reserved

 

 

 

 

 

 

 

on

on

 

15

 

12

 

11

8

3

 

on

off

 

14

 

9

 

6

4

1

(*)

 

 

 

 

 

 

 

 

 

 

 

off

on

 

13

 

10

 

5

2

0

 

(*) Default

 

 

 

 

 

 

 

 

 

 

Hard Disk Drive Power On Delay

 

 

 

 

RMT_START

DLY_START

Description

 

 

 

 

 

 

 

 

 

off

 

off

 

Motor (spin) up when powering on

 

on

 

off

 

Motor (spin) up after START UNIT command

(*)

off

 

on

 

Motor (spin) up after 12xSCSI ID ms

 

on

 

on

 

Reserved

 

 

 

(*) Default

SCSI ID Dip Switches

 

 

 

 

 

 

 

 

 

DLY_START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RMT_START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 0

 

Default setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DLY_START

on

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RMT_START

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 1

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 0

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

4

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL1 IDSEL0

Slot1

Slot2

Slot3A

Slot4

Slot5A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

IDSEL 1=off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 0=off

off

off

Resv.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

IDSEL 1=on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

on

15

12

11

8

3

 

 

 

 

 

 

 

 

 

 

 

IDSEL 0=on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

IDSEL 1=on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDSEL 1=off

on

off

14

9

6

4

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

IDSEL 1=off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

on

13

10

5

2

0

 

 

 

 

 

 

 

 

 

 

 

IDSEL 0=on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hardware Setup

SCSI ID Setting

IV.

 

 

 

AP 3000 Hardware Reference Guide

33