6.3.7Enabling the WriteCache
You may enable the RAID controller’s WriteCache option to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1.From the Management Menu, select Objects > Adapter, then press <Enter> to display the adapter properties.
2.Select Disk WC, then press <Enter> to turn the option On (enabled).
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
|
|
|
|
|
|
|
|
| Adapter 0 |
|
| |
|
|
|
|
|
|
| Rebuild Rate |
| = 30 |
|
| |
|
|
|
| ObjectsChk Const Rate = 30 |
| |||||||
| Management | MenuAdapter |
| |||||||||
|
| Drive | FGI Rate | = 30 |
|
| ||||||
Configure | Virtual |
| BGI Rate | = 30 |
|
| ||||||
Initialize | Physical |
| DriveDisk | WC | = Off |
| ||||||
Objects |
|
|
|
|
| Read | Ahead | = On |
| |||
Rebuild |
|
|
|
|
| Bios | State | = Enable |
| |||
Check Consistency |
|
|
|
|
| |||||||
|
|
|
| Stop | On Error | = No |
| |||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| Fast | Init | = Enable |
| ||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Auto | Rebuild | = On |
| ||
|
|
|
|
|
|
| Auto | Resume | = Enable |
| ||
|
|
|
|
|
|
| Disk | Coercion | = 1GB |
| ||
|
|
|
|
|
|
| Factory Default |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
3.When finished, press any key to continue.
Chapter 6: RAID Configuration |